Operating Instructions
Four-indent crimping tool DigiCrimp® with digital display and wear monitoring
NOTE
Do not crimp the gauge or other similar objects as this may damage the crimper. Always avoid
crimping solid materials such as steel at hardness levels above 35 HRC.
4. Changing the contact bushing
•
Unscrew the central socket-head screw on the mounted contact bushing (3) using an SW 2.5 mm Allen
key, using another Allen key on the other side for countering as necessary.
•
Remove the contact bushing (3).
•
Fasten the optional contact bushing (3) by the same sequence in reverse.
5. Changing the battery
A type 2025 battery for the digital display will last around
a year depending on how often you use the crimper. You
will need to change the battery after this period. Open the
battery compartment upwards in the direction of the arrow
for easy battery removal and replacement.
Info
Always set your crimper to the lower setting (reference setting) before you insert a new battery.
Info
You will always need to recalibrate your crimper (CAL) after a battery change.
See 9. Calibration after a battery change, for how to proceed. Always dispose of batteries at approved
recycling collection points.