INSTALLATION
STEP
1
Determine
the
Header
Bracket
Location
To prevent possible SERIOUSINJURYor DEATH:
• Headerbracket MUST be RIGIDLYfastenedto
structural support on header wall or ceiling, otherwise
garage door might not reverse when required. DO NOT
install header bracket over drywall.
• Concreteanchors MUST be used if mounting header
bracket or 2x4 into masonry.
• NEVERtry to loosen, move or adjust garage door,
springs, cables, pulleys, brackets, or their hardware,
all of which are under EXTREME tension.
• ALWAYScall a trained door systems technician if
garage door binds, sticks, or is out of balance. An
unbalancedgarage door might not reversewhen
required.
Installation procedures vary according to garage door
types. Follow the instructions which apply to your
door.
1. Close the door and mark the inside vertical
centerline of the garage door.
2. Extend the line onto the header wall above the
door.
You can fasten the header bracket within 4 feet
(1.22 m) of the left or right of the door center
only if a torsion
spring or center bearing plate
is in the way; or you can attach it to the ceiling
(see page 13) when clearance
is minimal.
(It
may be mounted
on the wall upside down if
necessary,
to gain approximately
1/2" (1 cm).
If you need to install the header bracket on a 2x4
(on wall or ceiling), use lag screws (not provided)
to securely fasten the 2x4 to structural supports as
shown here and on page 13.
3. Open your door to the highest point of travel as
shown. Draw an intersecting horizontal line on the
header wall above the high point:
• 2" (5 cm) above the high point for sectional door
and one-piece door with track.
• 8" (20 cm) above the high point for one-piece
door without track.
This height will provide travel clearance for the top
edge of the door.
NOTE: If the total number of inches exceeds the
height available in your garage, use the maximum
height possible, or refer to page 13 for ceiling
installation.
Header Wall
Unfinished
Ceiling _
Vertical Centerline
of Garage Door
_
PTIONAL
CEiLiNG
MOUNT
FOR
HEADER
BRACKET
2x4
Structural
Supports
l
eader Wal_
_
_2"
(5 cm)
Track
of Travel
--Door
Sectional
door with curved
track
Header Wall
Track
Highest Point
of Travel
One-piece
door with horizontal
track
Door
Hardware
Wall
o crn)
Highest
._
Point
of Travel
One-piece
door without
track:
jamb hardware
-leader Wall
8" (20 cm)
Highest
Point
of Travel
One-piece
door without track:
pivot hardware
12