Ridgid Kollmann SeeSnake KD-200 Manual Del Operador página 18

Ocultar thumbs Ver también para SeeSnake KD-200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Kollmann
The centering guide assembly consists of two parts - the
steel c-ring and the plastic centering guides. See Figure 23.
C-Ring
Figure 23 – The Centering Guide Assembly Components.
You should generally use 3 guide assemblies.
To Install the Centering Guide Assemblies:
1. Position the c-rings onto the spring assembly. This
can be accomplished by either placing the c-rings: a)
onto the push cable just behind the tapered end of the
spring assembly; or b) sliding them over the camera
head. Either method works well. If you use method a),
be sure to open the ring far enough to avoid "scarring"
the cable. See Figure 24. Regardless of the method,
place all c-rings onto the spring assembly before in-
stalling the first centering guide. You will need 2
c-rings for each centering guide, and 3 centering
guide assemblies generally work best in applica-
tions. However, we recommend you experiment to
find the best methods for local conditions.
Pull C-Ring
Open
Figure 24 – To place the c-rings onto the cable, pull the
c-rings with four fingers to open the ring far
enough to slip over the cable without touch-
ing the cable. Slide the c-rings onto the
spring assembly. Another method is to
place them over the camera head.
2. Place the centering guide over the spring assem-
bly. You will notice the centering guide has a cut
through one side so the guide can be opened to
slide over the spring assembly.
3. Position the cut side of the centering guide 180 de-
grees from the opening in the c-rings. See Figure 25.
16
Standard and Mini SeeSnake Diagnostic Equipment
Centering Guide
Ridge Tool Company
Opening of C-Ring is 180°
from Centering Guide cut side
Figure 25 – Position the cut side of the guide 180 degrees
from the c-ring openings.
4. Press the closed portion of the c-ring into the grooved
portion of the centering guide. The C-ring will snap in
place. Repeat with other c-ring on the other side of the
centering guide. See Figure 26.
Press
Figure 26 – Press the closed portion of the c-ring into
the groove of the centering guide. Repeat
on the opposite side of guide.
To Remove the Centering Guide Assemblies:
1. You will need a flat blade screw driver. Place the
flat tip of the screwdriver between the c-ring and the
base of the spike. Pry or snap the ring off. Repeat on
the other c-ring. See Figure 27.
Figure 27 – Place flat tip of screwdriver between c-ring
and base of spike and snap c-ring off the
groove.
Cut side of
Centering Guides
(underneath)
Press

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido