OPERATION
BB) If Using the PHOTO EYE for transformer control, first install the
PHOTO EYE Cable:
Photo EYE Mounting Location Advice:
Placing the sensor in areas receiving less sunlight at dusk (east side of
house, behind trees and bushes, under a deck) will have the transformer
come on earlier in the evening.
Mounting the photocell in brighter locations will have the transformer
come on when it has become darker out.
Avoid pointing the sensor at nighttime light sources such as windows,
porch lights, and street lights. This light may prevent the Photo Eye from
turning the transformer on.
A) Make sure power is off and transformer is NOT plugged into an
electrical outlet.
B) Unscrew the photocell connector dust cap from the transformer and
plug the photocell bi-pin connector into the mating "D" shape socket. Screw the
bi-pin cap onto the socket to provide a water tight connection. Note that the bi-
pin connector is polarized and can be inserted into the socket only one way.
C) Mount the photocell bracket on a wall or other solid surface with the
screws provided. Snap the sensor into the bracket. Route or coil the excess wire
to protect it from lawn mowers, trimmers, etc..
D) Plug power supply cord into standard 115/120 volt receptacle. NOTE:
The power supply cord must be plugged into a weather tight receptacle
equipped with a Ground Fault Interrupter (GFCI).
The photo eye operation can be tested by turning the transformer mode to TEST.
8