5.9 receiver

The receiver unit allows data exchange between the thermostat and the boiler.
A button with coloured LEDs indicates system status.
LED
Green
Green
Red
6. TEChnICal sPECIfICaTIOns
Power supply
Consumption
Relay output
Electrical/
Thermostat
Receiver
mechanical
Colour
Casing material
Temperature sensor
Wi-Fi standard
Wi-Fi frequency
RF frequency
RF distance
Wi-Fi
Antenna
Safety
Protocol
Network type
(*) Any obstacles or walls can reduce the WiFi signal range. In this case, bring the
gateway closer to the router, or use a WiFi extender.
56
EN
Status
ON
FLASHING
FLASHING
cod. 3541S181 - Rev. 00 - 09/2020
Functionality
Power ON
Data transmission
WIFI or RF connection search
100 ~ 240Vac, 50 / 60 Hz
1.2W
Voltage-free - 0.25A – 230Vac, 2A - 30Vdc
90 x 90 x 22
86 x 86 x 21
Black + silver
ABS + aluminium
built-in
802.11 b/g/n
2.412 GHz – 2.484 GHz
868 MHz [FSK]
max 40m in free field (*)
built-in
WEP / WPA - PSK / WPA2 - PSK
IPv4, TCP
STA