A
How to secure the lever handle.
Close the stop valve before starting work.
1. Insert a flat-blade precision screwdriver
into the clearance between the lever handle
and the cover, and lift and remove the cover.
(ill. 14)
2. Lift the lever handle and retighten the
setscrew with a hexagonal wrench (2.5mm)
3. Pass the cover over the lever handle,
press it into the counter surface and mount
it. (ill. 15)
B
To clean the nozzle screen:
1. Loosen and remove the set screw using a hexagonal wrench (2 mm).
(ill. 16)
2. Insert the flat-blade precision screwdriver in the notch between the
nozzle screen case and the spout, and remove the nozzle screen case.
Pay attention not to lose the O-ring of the nozzle screen case.
MAINTENANCE
ill. 15
Pay attention to the
direction of the cover.
Mount cover.
ill. 16
Flat-blade
precision
screwdriver
Spout
O-ring
(Semi-
transparent)
10
ill. 14
Flat-blade precision
screwdriver
Lever
Handle
Cover
Hexagonal wrench
(2.5mm)
Notch
Hexagonal wrench
(2mm)
Nozzle screen
case
Set screw
(M3x7)
Remove Cover