How do I install for new construction?
Route Supply Wires
STEP 2
Route supply wire from circuit breaker to top of wall can. Remove
knockout and attach the supply wire with a strain relief connector,
leaving 6 inches of wire lead for later use. Connect supply ground
wire to grounding screw in wall can (See Figure 3).
Proceed to PART TWO.
__________________________
After you have followed all instructions in PART ONE, for either new construction or an existing wall, you are
How do I insert the heater assembly into the wall can?
Install Heater Assembly
STEP 1
Place heater assembly inside wall can and secure
with two screws (provided).

Wire Connections

STEP 2
Connect the 2 heater wires to the 2 supply wires us-
ing electrical insulated wire connectors (see Figure
5). Push wires into wiring junction box.
Install Grill
STEP 3
Secure grill with the screws provided. Slide thermo-
stat knob onto shaft. Turn power on at the electrical
panel board.
Important: Before turning on power, be sure the
thermostat knob is turned counter clockwise to the
lowest setting, and the switch is in the "FAN" or
"AUTO" position.
Page 4
Part One
How do I install in an existing wall?
STEP 3
Insert wall can into opening. Keeping front of wall can flush with
wall, secure to wall stud with screws through the four larger (3/16
inch) holes. Connect supply ground wire to grounding screw in
wall can (See Figure 3).
Proceed to PART TWO.
Part Two
ready to install the heater assembly.
(continued)
__________________________
Mount Wall Can
__________________________
Supply
Ground
Wire
Figure 5