Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Gala Gar
5.3 Welding parameters table (for reference only)
Electrode dia. (mm)
1.0
1.6
2.0
2.5
3.2
4.0
5.0
6.0
Note: This table is suitable for mild steel welding. For other materials, consult related
materials and welding process for reference.

6. CAUTION

1. Working Environment
1. Welding should be carried out in dry environment with its humidity of 90% or less.
2. The temperature of the working environment should be between -10℃ to 40℃.
3. Avoid welding in the open air unless sheltered from sunlight and rain. Keep it dry anytime
and do not place it on wet ground or in puddles.
4. Avoid welding in dusty area or environment with corrosive chemical gas.
5. Gas shielded arc welding should be operated in environment without strong airflow.
2. Safety Tips
Over-current/over-voltage/over-heating protection circuit is installed in this machine. If the
input voltage or the output current is too high or machine inside temperature over heating inside,
the machine will stop automatically. However, excessive use (e.g. too high voltage) of machine
may also damage machine, so please note:
2.1 Ventilation
High current passes when welding is carried out, thus natural ventilation can not satisfy the
machine's cooling requirement. Maintain good ventilation through the louvers of the machine. The
minimum distance between the machine and any other objects in or near the working area should
be 30cm. Good ventilation is of critical importance for the normal performance and lifespan of the
machine.
2.2 Welding operation is forbidden while the machine is overload. Remember to observe the
max load current at any moment (refer to the corresponding duty cycle). Make sure that the
welding current should not exceed the max load current. Overload could obviously shorten the
machine's lifespan, or even damage the machine.
2.3 Over-voltage is forbidden.
Regarding the power supply voltage range of the machine, please refer to "Main Parameters"
table. This machine is of automatic voltage compensation, which enables the maintaining of the
voltage range within the given range. In case that the input voltage exceeds the stipulated value, it
would possibly damage the components of the machine.
Recommended welding
current (A)
20~60
44~84
60~100
80~120
108~148
140~180
180~220
220~260
Recommended welding
voltage (V)
20.8~22.4
21.76~23.36
22.4~24.0
23.2~24.8
23.32~24.92
24.6~27.2
27.2~28.8
28.8~30.4
17