TECHNICAL DATA:

- Power supply
- Working temperature
- Working frequency
- Sensitivity Anemometer
- Sun Sensor Sensitivity
- Packaging dimensions
- Container
CONNECTIONS OF THE CN1 TERMINAL BOARD:
1 : 230V~ Line input (Phase).
2 : 230V~ Line input (Neutral).
INITIAL FUNCTIONING CONDITION
The device can only work in conjunction with one or more SEAV electronic control units pre-
arranged for radio reception of information relating to the state of the sensors. For the func-
tioning, it will be necessary to carry out the programming operation of the Wireless Sensor
on the control unit to which it will be coupled (see par."CODE Sending of Radio Identifier" ).
In the default factory setting, each Wireless Sensor example produced has a different
identifier.
WIND SENSOR FUNCTIONING
The device will send to the control unit to which it has been coupled, a closing control every
time the set Wind threshold is exceeded.
SUN SENSOR FUNCTIONING
The device will send to the control unit to which it has been coupled, a downward control
after 10 minutes of brightness higher to the threshold selected by means of the VR1 trim-
mer and displayed through the switching on of the SUN MONITOR LED; it will send an
upward control after 10 minutes of brightness lower than the selected threshold.
Select send sensor status information Fast / Slow:
The device, through the Connector CN3 allows you to select the radio sending of informa-
tion about the status of Sun sensor so Fast (= 2 minutes) or slow (Slow = 10 minutes).
In the factory configuration the selection of radio transmission speed is kind of slow (CN3
pos. 3-4), to speed up the reaction time of the sun sensor (commands sent every 2 min-
utes about instead of every 10), place CN3 pos. 4-5.
The operation must be performed with the sensor is not powered.
Regulation of sensitivity to the Sun (5 ¸ 40 Klux)
The device allows to regulate the intervention threshold due to brightness, by means of
the VR1 trimmer. The switching on of the SUN MONITOR LED on the device indicates that
the Sun intensity exceeds the selected intervention threshold, in this way we will have a
reference to the current light conditions to establish the desired one
: 230V~ 50/60Hz 3W max.
: -10 ÷ 55 °C
: see model
: 5 ÷ 40 Km/h
: 5 ÷ 40 Klux.
: 240x185x110 mm.
: PC UL94V-0 (IP54)
PROGRAMMING KEYS AND INDICATOR LED
SEL Key: selects the type of function to memorise, the choice is indicated by the flashing of the
LED. By repeatedly pressing the key, it is possible to position oneself on the desired function. The
selection remains active for 15 seconds, displayed by the flashing LED, after which the control
unit returns to the original status.
SET Key:
carries out the programming of the function chosen with the SEL key.
Indicator LED:
LED on: option memorised.
LED off: option not memorised.
LED flashing: option selected.
———————————— M A IN M EN U —————————————
LED Reference
LED Off
1) CODE
Send RFID = OFF
2) SPEED
Wind Safety 25 Km/h
3) WIND
Wind Safety = OFF
4) SUN
Sun Sensor = OFF
5) RAIN
Not used
6) TEST
Test Sensors = OFF
1) CODE : (Sending of Radio Identifier)
The coupling of the Wireless Sensor to a control unit must be carried out as follows: activate
the Wireless Sensor programming procedure on the control unit (see control unit technical
manual), with the SEL key position yourself on the flashing of the CODE LED and press the
SET key for about 1-2 seconds: at the same time, the Sensor will send an identifying code
signalled by the flickering of the CODE MONITOR LED.
Check that in the coupled control unit there is confirmation of the occurred Sensor program-
ming (see control unit technical manual). In this way, the Wireless Sensor is coupled to
the control unit and it will send to the same controls dependant upon the meteorological
conditions.
Repeat the operation in case the same Sensor is to be programmed on other control units.
2) SPEED : ( Programming of Wind Safety threshold )
Display of the programmed Wind threshold
The display of the wind Safety threshold selection is carried out as follows: with the SEL key
position yourself on SPEED LED, the LED will start to double flash for the number of times
equal to the wind Safety threshold in the memory (to every double flash of the SPEED LED
corresponds an increase of 5 Km/h), (example: 5 flashes of SPEED LED = 25 Km/h).
9
LED On
Send RFID = ON
Pgm. Wind Safety
Wind Safety = ON
Sun Sensor = ON
Not used
Test Sensors = ON