SITE PREPARATION

Preparation

Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket and hardware.
Completely retract the front leveling legs to allow the unit to
be moved into position. The front and rear leveling legs can
be adjusted from the front once the unit is in position.
Remove the drain pan from the base of the unit to avoid
damage, and allow for proper appliance dolly placement.
The grille assembly should be removed prior to moving the
unit. To remove, pull out on the bottom edge of the grille and
rotate upward. Cut cable ties that attach the network cable
to the grille, then disconnect the network cable. Remove
three grille bolts from the grille, then pull grille forward to
remove. Refer to the illustration below.
CABLE TIE
NETWORK
CABLE
GRILLE
BOLT
Grille removal.
|
6
Sub-Zero Customer Care 800.222.7820

Anti-Tip Bracket

WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
Use the centerline locating holes to position the anti-tip
bracket in the center of the opening. The bracket must be
positioned 24"
from the front of the opening to the
(610)
back of the bracket. This depth will increase to 26"
a flush installation. Failure to properly position the anti-tip
bracket will prevent proper engagement.
Use all anti-tip bracket hardware as instructed for wood or
concrete floors.
IMPORTANT NOTE:
For wood or concrete floor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
In some installations the subflooring or
IMPORTANT NOTE:
finished floor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.
ANTI-TIP HARDWARE
1
Anti-tip bracket
12
#12 x 2
1
/
" pan head screws
2
3
3
/
"–16 x 3
3
/
" wedge anchors
8
4
12
#12 flat washers
1
3
#8–18 x 1
/
" truss head screws
4
3
Nylon Zip-it
®
wall anchors
CENTERLINE
LOCATING HOLES
Anti-tip bracket.
for
(660)