SMA Solar Technology AG RSB-2S-US-10 Instrucciones De Instalación página 28

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Electrical Connection
5. Lead a silicone tube over the conductors inside the
Rapid Shutdown Box.
6. Strip off the conductor insulation by 8 mm (0.31 in).
7. In the case of fine stranded wire, provide each conductor with a bootlace ferrule.
8. Connect the conductors to a five-pole plug. Observe
the pin assignment.
9. Place the cable tie onto the silicone tube, tighten
and cut off the projecting end of the cable tie. This
connects the conductors and the silicone tube
together securely.
10. Plug the five-pole plug with the connected
conductors into the upper pin row of the terminal
block RSC.
11. Connect the Rapid Shutdown Boxes together. To do so, connect the incoming conductors to a
plug and plug this into the lower pin row of the connecting terminal block RSC, and always
connect the outgoing conductors to a plug and plug this into the upper pin row of the terminal
block RSC.
12. In the last Rapid Shutdown Box, plug the second
five-pole plug into the lower pin row of the terminal
block RSC and place a jumper wire between pins 3
and 4. Here, use a jumper wire that is rated for the
maximum system voltages or insulate the jumper
wire using a piece of one of the supplied silicone
tubes.
28
RSS-US-IA-xx-15
SMA Solar Technology AG
Installation Manual

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rsc-1x-us-10

Tabla de contenido