5. Safety regulations
Take suitable precautions to protect yourself and
your environment from potential hazards.
Never put the drill to any use other than that
intended.
Keep pneumatic tools safe from children.
Always concentrate while you work. Do not work if
you are tired.
Use only a quick-release coupling to connect up
the air supply.
It is imperative to use a pressure reducer to set the
working pressure.
Never use oxygen or combustible gases as an
energy source.
Always disconnect the tool from the air supply
before carrying out any repairs or maintenance
work.
Use only original replacement parts.
Wear the necessary protective clothing,
particularly goggles and safety gloves, when
working with the drill.
6. Putting into operation
Screw the supplied plug-in nipple into the air
connection after you have wound 2 to 3 layers of
sealing tape around the thread.
Insert the bit (max. Ø 10 mm) in the chuck and
tighten the chuck with the chuck key.
Important!
Never start the drill when the chuck key is still in
the chuck! Always remove the chuck key
immediately!
Depending on the size of the hole you want to drill,
you should always pre-drill with a smaller bit. The
tool can be used with restrictions as a screwdriver.
Use the selector lever (1) to change the direction of
rotation from -R- (reverse) to -F- (forward).
7. Maintenance and cleaning
Observance of the following maintenance
instructions will ensure that this quality tool gives you
years of troublefree service.
Clean the tool thoroughly as soon as you are finished
with your work.
Seite 5
Regular lubrication is vital for the long-term, reliable
operation of your drill. Use only special tool oil for
this purpose.
You can choose from the following options for
lubricating the tool:
7.1 By mist oiler
A complete conditioning unit includes a mist oiler and
is fitted to the compressor.
7.2 By hand
If your air system has neither a conditioning unit nor
a line oiler, you must feed 3-5 drops of special tool oil
into the air connection each time before you use your
drill. If the pneumatic tool has not been used for
several days, you must feed 5-10 drops of oil into the
air connection before you switch on.
Keep your pneumatic tool in dry rooms only.
Accessories
Special oil for pneumatic tools 500 ml
Art. No. 41.383.10
The warranty does not cover:
Wearing parts
Damage caused by an unacceptable level of
working pressure.
Damage caused by unconditioned compressed air.
Damage caused by improper use or unauthorized
tampering.
GB
5