4 Servicing

4.1 Service Intervals

Component
Complete Assembly
Check for air leaks.
Filtration
Check the pressure gauges during purging for excessive back pressure.
Filtration
Replace the adsorption filter media
Filtration
Replace the coalescing filter elements and automatic drains
(1) Unlike oil aerosol removal filters which are changed annually to guarantee compressed air quality, the lifetime of an oil vapour removal filter can be attributed to various factors
and require more frequent changes. Factors affecting the lifetime of adsorption filters are:
Oil vapour concentration - The higher the inlet concentration of oil vapour, the faster the activated carbon capacity will expire.
Bulk oil - Adsorption filters are designed to remove oil vapour and odours, not liquid oil or aerosols. Poorly maintained or non-existent pre-filtration will cause the OVR filter capacity
to quickly expire.
Temperature - Oil vapour content increases proportionally to inlet temperature, reducing element life. Additionally, as temperature increases, the adsorption capacity decreases,
again reducing element life.
Relative Humidity or Dewpoint - Wet air reduces the adsorptive capacity of the carbon.
Compressor oil changes - When compressor oil is changed, the new lubricant burns off "light ends" which increases the oil vapour content for hours or even weeks
afterwards. This increase in oil vapour content is adsorbed by the OVR filter, significantly reducing its adsorptive life.
ACS / AC element performance is based upon a maximum oil vapour inlet concentration of 0.018mg/m
These elements should be replaced upon detection of vapour, odour or taste.
Key:
Check
10
Description of Service Required
Operation
(1)
3
, with compressed air at 21
Service recommended every:
See Note (1)
o
C and a pressure dewpoint of -40
Replace
o
C PDP.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Baf015

Tabla de contenido