Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL misted 30 amp power suppmy cord.
Use a UL misted strain remief,
Disconnect
power before making emectrical connections.
Connect neutraB wire (white or center wire) to center
terminal
(silveO,
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect remaining
2 supply wires to remaining
2 terminams (gored).
Securemy tighten
aiBemectricat connections.
Failure to do so can resumt in death, fire, or
emectrical shock,
1. Disconnect
power.
2. Remove the hold-down screw and terminal block cover,
Fire Hazard
Use 10 gauge somid copper wire.
Use a UL misted strain relief=
Disconnect
power before making emectricamconnections.
Connect neutraB wire (white or center wire) to center
terminal
(silver),
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 suppmy wires to remaining
2 terminals
(gored).
SecureBy tighten
aH emectrical connections.
FaiBure to do so can resuJt in death, fire, or
emectrical shock.
3. Assemble a 3/,,,(1.9 cm) UL listed strain relief (UL marking on
strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Put power supply cord through the strain
relief. The strain relief should have a tight fit with the dryer
cabinet and be in a horizontal position.
A. Neutral grounding
wire (green with yellow stripes)
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
4.
Now complete installation following instructions
for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)