8.1
Zoom
You can zoom in and out of partial areas. Place the mouse pointer on the bar
graph and scroll. Use the horizontal scroll bar to display further measurements.
8.2
Context menu
The bar graph can be copied,
saved as an image, printed and
zoomed in the context menu.
Technical data
Accuracy (absolute)
Resolution
Memory
Measuring interval
18
EN
Ambient temperature
-40°C ... 70°C
±1°C (-10°C ... 40°C)
±2°C (-40°C ... -10°C,
+40°C ... 70°C)
Relative humidity
0% ... 100%
±3% (40% ... 60%)
±3,5% (20% ... 40%, 60% ... 80%)
±5% (0% ... 20%, 80% ... 100%)
0,1% rH, 0,1°C, 0,1°F
20010 individual measurements
2s ... 24h
Copy
Save image as...
Page setup...
Print...
Show point values
Unzoom (decrease)
Cancel all zoom /
pan actions
Reset scaling
-40°F ... 158°F
±1,8°F (14°F ... 104°F)
±3,6°F (-40°F ... -14°F,
+104°F...158°F)