11. Troubleshooting guide
Caution!
Before troubleshooting, switch off the equipment and remove the battery.
The table below contains a list of fault symptoms and explains what you can do to remedy the problem
if your equipment fails to work properly. If the problem still persists after working through the list, please
contact your nearest service workshop.
Fault
The equipment
does not work
Equipment operates
intermittently
Anl_GATH_E_20_Li_OA_SPK7.indb 22
Anl_GATH_E_20_Li_OA_SPK7.indb 22
GB
Possible cause
- Battery empty
- Battery is not correctly inserted
- Loose connection (external)
- Loose connection (internal)
- ON/OFF switch defective
- 22 -
Remedy
- Charge battery
- Remove battery and insert again
- Consult a specialist workshop.
- Consult a specialist workshop.
- Consult a specialist workshop.
05.11.15 11:31