OPERATION AND MAINTENANCE MANUAL FOR
SERIES 170PG AND 180PG WELD FLUX SCALERS
Series 170PG and 180PG Weld Flux Scalers and Needle Scalers are designed for removing weld
splatter or other unwanted surface deposits from metal.
READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THIS PRODUCT.
IT IS YOUR RESPONSIBILITY TO MAKE THIS SAFETY INFORMATION
AVAILABLE TO OTHERS THAT WILL OPERATE THIS PRODUCT.
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
Always install, operate, inspect and maintain this
•
product in accordance with all applicable standards
and regulations (local, state, country, federal, etc.).
Always use clean, dry air at 90 psig (6.2 bar/620 kPa)
•
maximum air pressure at the inlet. Higher pressure
may result in hazardous situations including excessive
speed, rupture, or incorrect output torque or force.
Be sure all hoses and fittings are the correct size and
•
are tightly secured. See Dwg. TPD905- -1 for a typical
piping arrangement.
Ensure an accessible emergency shut off valve has
•
been installed in the air supply line, and make others
aware of its location.
Always wear eye protection when operating or
•
performing maintenance on this tool.
Always wear hearing protection when operating this
•
tool.
Always use Personal Protective Equipment
•
appropriate to the tool used and material worked.
This may include dust mask or other breathing
apparatus, safety glasses, ear plugs, gloves, apron,
safety shoes, hard hat and other equipment.
Prevent exposure and breathing of harmful dust and
•
particles created by power tool use:
Some dust created by power sanding, sawing,
grinding, drilling and other construction activities
contains chemicals known to cause cancer, birth
defects or other reproductive harm. Some
examples of these chemicals are:
- - lead from lead based paints,
- - crystalline silica from bricks and cement and
other masonry products, and
- - arsenic and chromium from chemically
treated lumber.
Refer All Communications to the Nearest
Ingersoll- -Rand Office or Distributor.
Ingersoll- -Rand Company 2002
Printed in U.S.A.
AND NEEDLE SCALERS
IMPORTANT SAFETY INFORMATION ENCLOSED.
PLACING TOOL IN SERVICE
USING THE TOOL
04577409
Do not use damaged, frayed or deteriorated air hoses
•
and fittings.
Keep clear of whipping air hoses. Shut off the
•
compressed air before approaching a whipping hose.
Always turn off the air supply and disconnect the air
•
supply hose before installing, removing or adjusting
any accessory on this tool, or before performing any
maintenance on this tool.
Do not lubricate tools with flammable or volatile
•
liquids such as kerosene, diesel or jet fuel. Use only
recommended lubricants.
Keep work area clean, uncluttered, ventilated and
•
illuminated.
Do not remove any labels. Replace any damaged label.
•
Your risk from these exposures varies, depending
on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are
specially designed to filter out microscopic
particles.
Keep others a safe distance from your work area, or
•
ensure they use appropriate Personal Protective
Equipment.
This tool is not designed for working in explosive
•
environments, including those caused by fumes and
dust, or near flammable materials.
This tool is not insulated against electric shock.
•
Be aware of buried, hidden or other hazards in your
•
work environment. Do not contact or damage cords,
conduits, pipes or hoses that may contain electrical
wires, explosive gases or harmful liquids.
Keep hands, loose clothing, long hair and jewelry
•
away from working end of tool.
F
Form P7466
Edition 2
E
January, 2002
P