Translation of the original instructions
CONNECTING THE BATTERY TESTER
1- Ensure that the area is well ventilated before performing a test.
2- Tester for 12 V batteries (including START/STOP batteries)
3- Before performing a test on the battery, make sure that the ignition is off, that the accessories are not working. Close
all the doors and the boot.
4- Make sure that the battery connections are clean. If necessary, clean them using a wire brush.
Any presence of oxidation between the tester terminals and the battery connectors or between the battery connectors
and the battery terminals reduces the effectiveness of the tester.
5- Connect the negative (black) terminal to the negative terminal of the battery. Connect the positive plug (red) to the
positive terminal of the battery.

SETTING UP THE DEVICE

1- Set the language :
1. Press Menu and then «Language».
2. Select the language then validate the choice by clicking OK
2- Date / time setting
1. Press Menu and then «Adjust time».
2. Press the up and down arrows to change the year. Press OK to confirm the change. Proceed in the
same way to set the date and time.

BATTERY TEST

1. On the Home screen, click OK to display the main menu
2. Select «battery test» in the main menu and press OK
3. Select the battery type using the arrows and click OK to confirm.
4. Select the standard written on the battery then validate (possible standards: CCA, BCI, CA, MCA, DIN, IEC, EN, SAE, GB)
5. «Setting Rate»: Enter the start current (indicated on the battery in Amps (A)) using the arrows then OK
6. The test starts, the screen displays the result.
Results display screen
Health status
Charge status
Result
Battery test result
Result
BATTERY OK
GOOD CONDITION, RECHARGE
REPLACE
CELL NOK, REPLACE
CHARGE, NEW TEST

START-UP TEST

1. Press «start test» in the main menu
2. Start the engine to start the test
3. The test starts automatically and displays the starting voltage obtained
PBT 550
Measured CCA current
Voltage
Internal resistance of the battery
CCA battery current
(entered by the user)
The battery is operational.
Battery in good condition but low state of charge.
The battery is nearing the end of its life.
A replacement should be considered.
A problem at the cell level is observed (short circuit.....). Replace the battery.
The battery is unstable. It must be recharged and tested again. If the
same result appears after charging, the battery is damaged and must
be replaced.
Analysis
EN
7
7