Maintenance And Care; Faults - Tornado BR Vario II Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Storing the appliance
Push the push handle lock up and swiv-
el the push handle down over the appli-
ance toward the fresh water reservoir
and lock it.
Align the appliance as shown above.
Note
To start again, slide the lock of the push
handle up and swivel the handle upwards.
Fault
Appliance cannot be started
Insufficient water quantity
Insufficient cleaning result
Brushes do not turn
Appliance vibrates.

Maintenance and care

Danger
Risk of injury!
Pull the plug from the mains before carrying
out any tasks on the appliance.
Warning
Risk of damage to the appliance on account
of water leakage. Remove the fresh water
reservoir before doing any work on the ap-
pliance.
Maintenance schedule
After the work
Warning
Risk of damage. Do not wash down the ap-
pliance with water and do not use aggres-
sive detergents.
Empty the fresh water reservoir.
Fill the fresh water tank with clear water
and rinse the appliance to avoid residue
buildup.
Remove the remaining water from the
fresh water tank.
Check the seal in the ball valve in the
fresh water reservoir.
Let the reservoir dry prior to closing
them to prevent odour creation.
Clean the outside of the appliance with
a damp cloth which has been soaked in
mild detergent.
Check the brushes for wear, replace if
required.
Clean the water distribution bars above
the brushes.

Faults

Remedy
Check if the mains plug is connected.
Socket fuse rating too low, look for proper socket.
Check fresh water level, refill tank if necessary.
Clean the ball valve in the fresh water reservoir.
Check and ensure that the fresh water reservoir is seated properly on the appliance.
Filter in the fresh water reservoir is plugged, clean filter.
Check hoses for blockages; clean if required.
Check the brushes for wear, replace if required.
Use brush rollers suited for the type of dirt and floor covering.
Check if foreign matters block the brushes; remove foreign matter if required.
Overcurrent protective switch was triggered. The overcurrent protective switch will allow the op-
eration after max. one minute.
Brush rollers are out of balance, replace the brush rollers.
Monthly
Clean the brush tunnel.
Yearly
Have the prescribed inspection carried
out by the customer service.
Maintenance Works
Replacing the brush rollers
Lay the device on its side.
Press the brush change key and simul-
taneously tilt the brush roller down-
wards.
Pull out the brush roller.
Place the new brush roller on the driver
and lock into place.
Maintenance contract
To ensure a reliable operation of the appli-
ance maintenance contracts can be con-
cluded with the competent Kärcher sales
office.
Frost protection
In case of danger of frost:
Empty the fresh water reservoir.
Push the button for detergent solution
until no more water is expelled.
Store the appliance in a frost-protected
room.
Faults
Danger
Risk of injury!
Pull the plug from the mains before carrying
out any tasks on the appliance.
Warning
Risk of damage to the appliance on account
of water leakage. Remove the fresh water
reservoir before doing any work on the ap-
pliance.
In case of faults that cannot be remedied
using the table below please contact the
customer service.
11
English

Publicidad

Tabla de contenido
loading

Tabla de contenido