Technical Specifications - Bosch ARD-AYZ12 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ARD-AYZ12

TECHNICAL SPECIFICATIONS

Electrical Characteristics
Power Supply Type
Operating Voltage Range 10 - 16 VDC
Absolute Maximum (non-
operating)
Maximum Input Current
Tamper Output
Max Cable Distance to
Controller
Output modulation
Card read distance*
Environmental Characteristics
Operating Temp. Range
Operating Humidity
Environment class
Dimensions
Height x Width X Depth
Weight
* Measured using Bosch Proximity Card (P/N ACD-ATR11ISO) or
equivalent. Range also depends on electrical environment and/
or proximity to metal.
Suitable for Outdoor Use
Bosch Sicherheitssyteme GmbH
Installation Manual | en
Linear type recommended
18 VDC
Standby: 280 mA
Read: 330 mA
Open collector, active low, max
sink current 30 mA
500 ft. (150 meters)
26-bit Wiegand
23.6 inch (60 cm)
-22°F to 145°F (-30°C to 63°C )
0 to 95% (non condensing)
IP 54
11.81 x 11.81 x 1.0 inch
(300 x 300 x 25.4 mm)
2.35 Lbs. (1066 g)
9
| V 1.2 | 2009.09

Publicidad

Tabla de contenido
loading

Tabla de contenido