2.20. The appliance is intended to be permanently connected to water main with a normally closed valve; do not
use a hose-set.
Heat flow. (See technical features).
Heating return. (See technical features).
Safety
valve
discharge.
features).
Charge-discharge. (See technical features).
Drain siphon.
Normally closed valve
Water main.
3.
FUEL.
Your stove is designed to operate with wood pellets; however, it can also work with other biomass fuels (ask
your dealer about this). If using a different type of biomass is possible, select it from the fuel selection menu (check
user manual). In most cases, the combustion basket is not the same as for wooden pellets.
ECOFOREST do not have any control on the quality of the fuel you use. For this reason, ECOFOREST cannot
guarantee the full output of your stove nor the eventual premature aging or eventual damage of the gas outlet. The
fuel's minimum requirements are specified below:
Diameter (mm)
Length (mm)
Granulometry (mm)
Calorific value (Kcal/kg)
Ash (% mass)
Humidity (%mass)
Oils
Grill and/or specific strangler.
4.

INSTALLATION.

The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to
geographic areas.
Air inlets and water connections will be missed in all drawings as section 4.16 indicates the minimum
security distances to be respected for their installation.
The power socket to which the stove is plugged should meet the following requirements:
4.1.
Ground connection must comply with the specific applicable regulations.
4.2.
Differential switch with the correct amperage. It must comply with the specific applicable regulations (check
technical specifications of the stove).
4.3.
Single-phase AC of ~230/240V – 50Hz and pure sine wave.
4.4.
The plug must only be connected to a socket with the technical characteristics of the plug in question.
4.5.
Easily accessible power socket. If the power socket can't be accessed due to the characteristics of the
electrical installation, an all-pole disconnection switch must be installed.
(See
technical
Pellets
6
5-25
— —
≥ 4300
< 1.5
< 12
— —
ORIGINAL
ELECTRICAL CONNECTION.
29
Olive pits
— —
— —
3 - 4
≥ 3800
< 1.5
< 12
No oil content
SPECIFIC
Drawing 2
Almond shells
— —
— —
6 - 8
≥ 3700
< 1.5
< 12
— —
SPECIFIC