Technical parameters
Outputs
Output indication:
Output relays separated
from all internal circuits:
Insulation between COM
potentials:
Isolates. voltage open
relay contact:
SSR (Electronic Relay):
Switching voltage:
Switching output:
Surge current:
Relay 6A:
Switching voltage:
Switching output:
Minimum switching load:
Mechanical life:
Electrical life AC1:
Relay 10A:
Switching voltage:
Switching output:
Surge current:
Minimal switched current:
Switching frequency without
load:
Switching frequency with
rated load:
Mechanical life:
Electrical life AC1:
Communication
Installation BUS:
Unit status indication:
Power supply
Supply voltage / tolerance:
Dissipated power:
Rated current:
Power status indication:
Connection
Terminal:
Operating conditions
Operating temperature:
Storing temperature:
Protection degree:
Overvoltage category:
Pollution degree:
Operating position:
Installation:
Design:
Dimensions and weight
Dimensions:
Weight:
TECHNICAL SUPPORT | E-mail: support@inels.com | Mobil: +420 778 427 366 | Tel.: +420 573 514 276, +420 573 514 211 | Fax: +420 573 514 227 | www.inels.com
Made in Czech Republic
SA3-022M
yellow LED
reinforced Insulation
(Cat. II surges by EN 60664-1)
reinforced Insulation
(Cat. II surges by EN 60664-1)
1 kV
4x NO (OUT3 - OUT6)
20 - 240 V AC
480 VA
20 A, t ≤ 16 ms
12x NO (RE1 - RE6, RE11 - RE16),
1x HW block changeover (OUT1, OUT2)
250 V AC, 24 V DC
1500 VA / AC1; 300 VA / AC15; 180 W/DC, AC3
500 mW (12 V / 10 mA)
10x10
6
6x10
4
4x NO (RE7 - RE10)
250 V AC, 24 V DC
2500 VA/AC1, 240 W/DC
30 A max. 4s at 10%
100 mA
1200 min
-1
-1
6 min
3x 10
7
5
0.7x 10
BUS
green LED POWER
27 V DC, -20 / +10 %
max. 3W
100 mA (at 27V DC), from BUS
green LED RUN
2
2
max. 2.5 mm
/1.5 mm
with sleeve
-20 to +55 °C
-30 to +70 °C
IP20 device, IP40 mounting in the switchboard
II.
2
any
switchboard on DIN rail EN 60715
6-MODULE
90 x 105 x 65 mm
307 g
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com
Warning
Before the device is installed and operated, read this instruction manual carefully and with full
understanding and Installation Guide System iNELS3. The instruction manual is designated for
mounting the device and for the user of such device. It has to be attached to electro-installation
documentation. The instruction manual can be also found on a web site www.inels.com. Attention,
danger of injury by electrical current! Mounting and connection can be done only by a professional
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations.
Do not touch parts of the device that are energized. Danger of life-threat! While mounting,
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms,
directives and special regulations for working with electrical equipment. Before you start working
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This
instruction manual contains only general directions which need to be applied in a particular
installation. In the course of inspections and maintenance, always check (while de-energized) if
terminals are tightened.
2/2