a) Independent charge cycle statistics
i.
Cycle overview: Expandable bar chart showing the time spent in each charge stage
and the charge capacity provided (in Ah) during each charge stage
ii.
Status: Confirms if the charge cycle was successfully completed or if it was ended
early/interrupted for some reason, including the reason/cause
iii.
Elapsed: The elapsed/total charge cycle time
iv.
Charge: Total capacity provided during the recharge stages (Bulk and Absorption)
v.
Maintain: Total capacity provided during the charge maintenance stages (Float,
Storage and Refresh)
vi.
Type: The charge cycle mode used; either a 'Built-in preset' or a custom 'User
defined' configuration
vii.
Vstart: Battery voltage when charging commences
viii.
Vend: Battery voltage when charging is complete (end of absorption stage)
ix.
Error: Displays if any errors occurred during the charge cycle, including the error
number and description
By selecting the full screen view the data is displayed in landscape view with significantly
more days visible at the same time.
22