Operating Instructions
T4000 Compact
8009212/TF93/2010-03-29 © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Technical data
Parameter
Can be used as per
EN ISO 13849-1 up to
Category/Performance
Level
Can be used as per
EN 62061
PFH
D
TM mission time
Rated insulation
voltage U
i
Rated transient with-
stand voltage U
imp
Resistance to vibration
Operating delay as of
1)
state change)
2)
Risk period
Discrepancy time of
both safety outputs
Start-up delay time
4)
Dwell time
Switching frequency
Mounting distance
between two read
heads or two actuators
EMC protection
requirements
1)
Corresponds to the risk time in accordance with EN 60947-5-3. This is the
maximum switch-off delay of the safety outputs after withdrawal of the
actuator.
2)
The error detection time is the time of an internal device error. At least one
of the two semiconductor outputs is switched off safely.
3)
When the operating voltage is switched on, the semiconductor outputs are
switched off and the signal contacts set to LOW potential during the start-
up delay.
4)
The dwell time of an actuator inside and outside the operating range must
be at least 0.5 seconds to ensure a safe detection of internal errors in the
evaluation unit (self-detection).
min.
In accordance with
EN 60947-5-2
3)
0.5 s
80 mm
To EN 60947-5-3
Value
typ.
max.
3/PL e
SILCL 2
–8
2.5 x 10
20 years
75 V DC
1.5 kV
180 ms
500 ms
120 ms
3 s
1 Hz
8
Chapter
157