10
Technical specifications CORREX
10.1 Interrupter potentiostat for enamelled hot-water storage tanks
Function
Plug-in potentiostat with integrated LED function indicator red/green for use in
enamelled hot-water storage tanks (interrupter potentiostat with potential-
dependent protective current regulation).
Mains supply
Voltage: 230 V ± 10 %
Frequency: 50/60 Hz
Power rating: < 4 VA
Technical parameters
Nominal potential: 2.3 V
Nominal current (secondary): 50 mA
Drive potential (secondary): max. 10 V at 50 mA
Indicators
Light-emitting diodes in housing cover
green: mains supply available; ready for operation
red: malfunction
Operation
Temperature range (plug-in potentiostat): 0 ...40 °C
Safety class: II (operation in enclosed spaces)
Housing
Dimensions (without Euro plug): L 80 x B 50 x H 45 mm
Weight (without anode cable): approx. 160 g
Operating Instructions CORREX
MP 2.3-900
®
®
MP 2.3-900
43