Operation; Warning - Remington REM-80-OFR-O Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fueling The Heater:
Kerosene
For optimal performance of this heater, it is
strongly suggested that Kerosene be used.
Kerosene has been refined to virtually eliminate
contaminants, such as sulfur, which can cause
a rotten egg odor during the operation of the
heater. Using diesel fuel can cause excess soot
production. Do not use Bio-Diesel as this fuel
will damage your heater's seals and filter.
- CSA certified for use with K-1 kerosene, no. 1 & no.
2 diesel, JP8/Jet A Fuel, no. 1 and no. 2 fuel oil.
DANGER
OR OPERATING. FIRE OR EXPLOSION
COULD RESULT.
CAUTION
WAYS FILL THE TANK OUTDOORS. BE
SURE THAT THE HEATER IS ON LEVEL
GROUND WHEN FUELING, AND NEVER
OVERFILL THE TANK.

WARNING

DRAININGS.
- NEVER use fuel such as, benzene, alcohol, white
glass, camp stove fuel, farm diesel, paint thinners,
or other oil compounds in this heater. THESE ARE
VOLATILE FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store Kerosene in the living space.
Kerosene should be stored in a well ventilated
area outside the living area.
- NEVER store Kerosene in direct sunlight or near a
source of heat.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE

OPERATION

NEVER REFUEL
THIS HEATER
WHILE IT IS HOT
NEVER FILL
THE FUEL TANK
INDOORS. AL-
DO NOT USE
GASOLINE OR
CRANKCASE
- NEVER use Kerosene that has been stored from
one season to the next. Kerosene deteriorates
over time. OLD Kerosene WILL NOT BURN
PROPERLY IN THIS HEATER.
NOTE: Kerosene should only be stored
in a blue container that is clearly marked
"Kerosene." Never store Kerosene in a red
container. Red is associated with gasoline.
Ventilation:
DANGER
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well
ventilated areas.
- Refer to Safety Information on pages 2-3 for
information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated
space of at least 2,800 square centimeters
(3 sq. ft) for each 100,00 Btu/Hr. (29 kW) of
heater output. Provide a larger opening if more
heaters are being used.
Minimum Ventilation Opening Needed
80-OFR-O
2.4 ft.
2
2230 cm
2
7
Kerosene Radiant Heater User's Manual
CARBON
MONOXIDE
POISONING MAY
LEAD TO DEATH!
125-OFR-O
3.75 ft.
2
3484 cm
2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rem-125-ofr-o

Tabla de contenido