Campbell Hausfeld PA208501 Manual De Instrucciones Y Funcionamiento
Campbell Hausfeld PA208501 Manual De Instrucciones Y Funcionamiento

Campbell Hausfeld PA208501 Manual De Instrucciones Y Funcionamiento

Purificador de aire / secador

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

See Warranty on page 3 for important information about commercial use of this product.
Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
The Campbell Hausfeld Air Cleaner /
Dryer is designed to remove dirt, most
contaminants, oil and water from
compressed air. It is a two part system
consisting of a coalescing filter which
removes most contaminants, oils and
condensed water and a desiccant dryer
which removes water vapor.
Unpacking
After unpacking the air cleaner / dryer,
carefully inspect for any damage that
may have occurred during transit.
Check for loose, missing or damaged
parts.
Safety Guidelines
This manual contains information that is
very important to know and
understand. This information is provided
for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
DANGER
Danger indicates
!
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION
Caution indicates a
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
DANGER
!
You
can create dust when you
cut, sand, drill or grind
materials such as wood,
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2005 Campbell Hausfeld/Scott Fetzer
Air Cleaner / Dryer
paint, metal, concrete, cement, or other
masonry. This dust often contains
chemicals known to cause cancer, birth
defects, or other reproductive harm.
Wear protective gear.
WARNING
!
This product or its
power cord contains chemicals known
to the State of California to cause
cancer and birth defects or other
reproductive harm. Wash hands after
handling.
This product is a part of a high pressure
system and the following safety
precautions must be followed at all
times along with any other existing
safety rules.
1. Read this instruction
manual before installing
this device on a
compressed air system.
Be thoroughly familiar
with the controls and
the proper use of the equipment.
2. Safety glasses must be worn during
operation. Always work in a well
ventilated area.
3. Do not exceed any pressure rating of
any component in the system.
4. Protect air lines from damage and
puncture.
5. Check air hoses for weak or worn
condition before each use. Make sure
all connections are secure.
6. Keep all nuts, bolts and screws tight
and ensure equipment is in safe
working condition.
This product is
DANGER
!
specifically
designed for compressed air service
ONLY. Use with any other fluid (liquid
or gas) is a misapplication and not
permitted. For example, use with or
injection of certain hazardous liquids
or gases in the system (such as alcohol
or liquid petroleum gas) could be
harmful to the unit or result in a
combustable condition or hazardous
external leakage. Campbell Hausfeld's
warranties are void in the event of
misapplication and assumes no
responsibility for any resulting loss.
Specifications
Maximum pressure: 150 PSIG (10 bar).
Maximum temperature: 125˚F (52˚C).
For parts, product & service information
visit www.chpower.com
Model PA208501
Service
Indicator
Coalescing Filter
MANUAL
Figure 1
Installation
WARNING
!
pressure from the system before
attempting to install, service, relocate
or perform any maintenance.
1. The air cleaner/dryer should be
located as close as possible to the air
tool or spray gun.
2. A shutoff valve should be installed
before the air cleaner/dryer so the
unit can be easily depressurized for
servicing. Securely mount the air
cleaner/dryer in a vertical position
using the mounting bracket supplied
with the unit.
3. Install a Campbell Hausfeld 3/8"
Filter (PA2121) before and after the
coalescing filter/dryer for optimum
performance. Connect the piping or
hose with airflow in the direction of
the arrows cast into the top of the
unit. Avoid using unnecessary
fittings, couplings, etc., that restrict
air flow.
4. Remove the bowl from the dryer
housing by pushing the bowl toward
the body and rotating bowl counter-
clockwise. Pull bowl down to remove
from housing.
5. Open bag of desiccant and pour into
Mounting Bracket
Dryer
Disconnect power
and release all
IN245502AV 9/05

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Campbell Hausfeld PA208501

  • Página 1 Mounting Bracket masonry. This dust often contains Indicator chemicals known to cause cancer, birth The Campbell Hausfeld Air Cleaner / defects, or other reproductive harm. Dryer is designed to remove dirt, most Wear protective gear. contaminants, oil and water from compressed air.
  • Página 2 Air Cleaner / Dryer Model PA208501 a. Shut off air flow to the air Installation valve. Make sure system pressure is (Continued) cleaner/dryer and depressurize 10 psig or less. system. bowl. Shake or tap bowl periodically 2. The only other servicing required for to settle desiccant.
  • Página 3 WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air accessory supplied or manufactured by Warrantor.
  • Página 4 à l’outil pneumatique MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2005 Campbell Hausfeld/Scott Fetzer IN245502AV 9/05 4 Fr...
  • Página 5: Service Technique

    Filtre de 9,5 mm (PA2121) en poussant le bol vers le corps et suriser le modèle avant d’enlever le bol Campbell Hausfeld en position avant en tournant au sens contraire des afin d’éviter des blessures personnelles et après le filtre/sécheur. Brancher les aiguilles d’une montre.
  • Página 6 Nettoyeur / Sécheur à Air Modéle PA208501 Certains Modèles À Service Sérieux et Extrême AVERTISSEMENT huiles, produits chimiques, nettoyants Ne pas Le bol AVERTISSEMENT AVERTISSEMENT domestiques, solvants, peintures et démonter sur ce vapeurs peuvent attaquer les bols en le bol du protecteur de bol pour autres modèle est fabriqué...
  • Página 7 DURÉE : De la date d'achat par l'acheteur original comme suit : Campbell Hausfeld (service standard et non annoncé) - un (1) an ; (service sérieux) - deux (2) ans, (service extrême) - trois (3) ans, IronForce de Campbell Hausfeld - un (1) an;...
  • Página 8: Descripción

    Descripción Informaciones Indicador de Servicio Abrazadera Generales de Este purificador de aire/secador Campbell Hausfeld está diseñado para Seguridad eliminar polvo, la mayoría de contaminantes, residuos de aceite y agua del aire comprimido. Es un PROPOSICIÓN DE CALIFORNIA 65 sistema de dos partes que consiste de PELIGRO un filtro de fusión para eliminar la...
  • Página 9: Funcionamiento

    Cierre el flujo de aire hacia el ADVERTENCIA bien instalado. libere purificador de aire/secador y libere 3. Instale un filtro Campbell Hausfeld la presión del sistema. toda la presión del sistema antes de (PA2121) de 9,5mm (3/8”) antes y sacar cualquier envase o podría b.
  • Página 10: Modelos Resistentes Y Modelos Robustos

    Purificador de Aire / Secador Modelo PA208501 Algunos Modelos Resistentes y Modelos Robustos ADVERTENCIA aceites para compresores, químicos, productos El envase ADVERTENCIA ADVERTENCIA para limpieza doméstica, solventes, desco- de esta pinturas y vapores, pueden dañarlos necte el envase del filtro de la cubierta unidad está...
  • Página 11: Garantía Limitada

    Garantía Limitada 1. DURACIÓN: Desde la fecha de compra por parte del comprador original, según se detalla: Campbell Hausfeld (Trabajo estándar y sin especificar) – 1 (un) año, (Trabajo pesado) – 2 (dos) años, (Trabajo extremo) – 3 (tres) años; IronForce de Campbell Hausfeld –...
  • Página 12 Air Cleaner / Dryer Model PA208501 Nettoyeur / Sécheur à Air Modéle PA208501 Purificador de Aire / Secador Modelo PA208501 For Replacement Parts, Call 1-800-543-6400 Please provide following information: Address parts correspondence to: -Model number The Campbell Group/Attn: Parts Dept.

Tabla de contenido