E031002AW
the place of installation.
Straps must be cut and carton removed.
Open both the side-doors with the special key and
remove the anchor bolt to the pallet which are
visibile at the bottom of the shoulder of the
machine.
To take the ironer off the pallet, slide the forks of
the shunter under the slide (make sure you don't
scratch the varnish) and lift the machine.
To take the drying ironer off the pallet, use two
steel bars with a minimum diameter of 20 mm and
at least 800 mm long, introducing them through
the two preset holes. Sling the machine and lift it
in a perfectly vertical position.
Handling
with
performed only by qualified staff.
NOTE: inside the packaging (above the drying
ironer), the are two slides through which you
introduce and take out the linen. The slides must
be mounted in the preset housing on the frontal
part of the machine
5. IDENTIFICATION OF THE MACHINE
Machine can be identified through an indicating
plate with its serial number, model, power and
technical characteristics. For spareparts and/or
reparing services you must have the exact serial
number of the model.
a
shunter
must
be
Tampering, removal and absence of the serial and
identification number or anything that does not
allow to identify the machine, make any operation
for installment and service difficult and warranty
will expire automatically.
6. INSTALLATION PREMISES
All the installation must be performed by qualified
staff. Place the machine on a flat surface in a
stable and horizontal way using the adjustable
feet at the bedplate on the sides. For a correct
use, functioning and service leave at least 500
mm of free space around the machine.
For a drying ironer the supporting surface must
have a minimum capacity of 500 kg/m²: for other
machines check their technical cards. The drying
ironer must be placed in a ventilated room (see
the law disposal), with a room temperature
between -10ºC and +40ºC.
Air-refresh must be maintained in proportion to the
air used by the machine while working: primary air
and secondary air for gas machines (see following
key plan), and requested air from moist air
aspirator for all the others (check the key plan).
MC/A 150
25 m
Metano
GPL
31 m
requested air for combustion of gas drying ironers
Ventilation air must be drawn directly from
outside, far from pollution sources, and the inflow
must be granted by permanent openings on the
walls of the room towards the outside. The
calculation of the net total free section must be
calculated according to the present laws.
12
24/11/04
MC/A 180
MC/A 210
3
3
3
/h
30 m
/h
31 m
/h
3
3
3
/h
36 m
/h
40 m
/h