Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

• Set the main operating parameters (e.g. the presence of an electric lock ON/OFF) in the options menu.
• If you have safety devices working with 8.2k contacts select the correct setting from the safety device menu.
• Before programming the gate travel distances select the correct motor in the "Motion" menu.
OPTIONS
SAFETY DEVICES
MOTION
Arrow
DISPLAY
to scroll
REMOTE
"PROG/OK"
to confirm
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
"PROG/OK"
to return to
MEMORISE
'remote'
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
Note:
10) Channel functions
Each radio control channel can be
"A","B","C","D"
set to one of
7 available functions:
-
TD sequential command
TAL limited opening
-
-
TA open
-
TC close
-
Block
-
CH2 second radio channel
-
No command
Operational indications
Pause time programming or
PAUSE
pause
for
TB FI
TA TD
reclosing (if activated)
FS CP
TC TAL
AUTO PROG
Automatic programming
TB FI
TA TD
under way
FS CP
TC TAL
OPENING
TB FI
TA TD
Opening stage
FS CP
TC TAL
STOP OPENING
Block during opening
TB FI
TA TD
FS CP
TC TAL
CLOSING
TB FI
TA TD
Closing stage
FS CP
TC TAL
STOP CLOSING
TB FI
TA TD
Block during closing
FS CP
TC TAL
Arrow
to exit
"PROG/OK"
MEMORISE
to confirm
[Nr...]
* * * * * * * * * * * * * * *
to memorise
*
*
* ACTIVATION 1
*
*
*
* * * * * * * * * * * * * * *
"PROG/OK"
CANCEL
to confirm
[Nr...]
* * * * * * * * * * * * * * *
to memorise
*
*
* ACTIVATION 1
*
*
*
* * * * * * * * * * * * * * *
"PROG/OK"
EXIT
to confirm
* * * * * * * * * * * * * * *
CANCEL
*
*
* ALL MEMORY ? *
PRESS ok to
* * * * * * * * * * * * * * *
OK
"PROG/OK"
CHANNEL A
to confirm
channel function A
CHANNEL B
channel function B
CHANNEL C
channel function C
Note: 10
CHANNEL D
channel function D
EXIT
PROGRAM
TB FI
TA TD
FS CP
TC TAL
TB FI
TA TD
FS CP
TC TAL
OUT OF POS
STOP PROG
TB FI
TA TD
FS CP
TC TAL
AUTO PROG
TB FI
TA TD
FS CP
TC TAL
SAFETY ERROR
TB FI
TA TD
FS CP
TC TAL
automatic
ERROR MOT1/2
TB FI
TA TD
FS CP
TC TAL
ERROR ENC1/2
TB FI
TA TD
FS CP
TC TAL
ERROR DIR1/2
TB FI
TA TD
FS CP
TC TAL
ERROR SENS1/2
TB FI
TA TD
FS CP
TC TAL
ACT. SAFETY EDGE
TB FI
TA TD
FS CP
TC TAL
ACTIVE SENSOR
PRESS the
PRESS the
MEMORISE
transmitter
[Nr...]
channel
transmitter
* * * * * * * * * * * * * * *
*
*
* ACTIVATION 2
*
*
*
* * * * * * * * * * * * * * *
PRESS the
PRESS the
CANCEL
transmitter
channel
[Nr...]
transmitter
* * * * * * * * * * * * * * *
*
*
* ACTIVATION 2
*
*
*
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
* CANCELLING
*
*
*
* * * * * * * * * * * * * * *
cancel all
memory
or press exit
Language choice:
• Press the right and left buttons simultaneously to
"PROG/OK"
enter the language submenu.
to change
the value
• Press the right and left buttons to change the
language: Italian to English.
• Press the "PROG/OK" button to confirm the
choice.

Alarm indications

Flashing on the display. You have to enter the programming mode to program the system.
During normal operation it indicates that the "automatic repositioning" procedure is about to
take place. In this case any commands received (TA, TC, TAL or TD) will automatically start
this procedure.
This happens when an N.C. contact is activated (FI, FS, CP) during encoder programming or
automatic repositioning. Once the passive state of the security devices has been reset the gate
will start moving again automatically. It also happens if a blackout occurs during programming.
Safety device test error. Check the condition of the safety devices and make sure that the
alarm cuts in when an obstacle interferes with the beam (indication white characters on a black
background). In case of anomalies replace the damaged safety device or bridge the contact
and deactivate the safety test (option menu).
This occurs when the programmer sends a command to the motor and nothing happens (motor
1/2 doesn't move). Check the Faston connections of motor 1/2 and the condition of the fuses
"F3", "F4" and then give another opening or closing command. If the motor still doesn't move
you are faced with either a mechanical problem or a problem with the programmer.
Encoder count error motor 1/2 . If this error occurs during normal motor operation it means
that there is a problem with one of the encoder signals. Check the relative connections and
carry out automatic repositioning.
Encoder direction error motor 1/2 : The gate movement direction is different from the encoder
setting (eg. the gate moves in the closing direction while the program is carrying out the
opening stage). Check motor 1/2 power supply connections.
Current sensor error motor 1/2 . When the gate is not moving this symbol means there is a
problem with the current sensor 1/2 .
Opening this contact will provoke a travel direction inversion during the closing stage and
during the opening stage.
If the sensor intervenes during the opening direction the gate inverts the travel direction immediately
and proceeds to the fully open position. If the sensor intervenes during the closing direction the gate
automatically inverts the travel direction of a few centimetres and then stops to free the obstacle.
21
MEMORISE
the same
[Nr...]
channel
* * * * * * * * * * * * * * *
again
*
*
CODE
*
*
MEMORISED
*
*
* * * * * * * * * * * * * * *
CANCEL
the same
[Nr...]
channel
* * * * * * * * * * * * * * *
again
*
*
CODE
*
*
CANCELLED
*
*
* * * * * * * * * * * * * * *
PROGRAM
TB FI
TA TD
FS CP
TC TAL
00.000.007
CC2X24
V0.10
press both arrows
simultaneously to enter
the language submenu
ITALIANO
FRANÇAIS
ENGLISH
NEDERLANDS
DEUTSCH
ESPAÑOL
"PROG/OK" to confirm

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

200/bl824s

Tabla de contenido