Setup The DMC-1910 Single Fiber
Media Converter
As with any electric device, you should place the equipment where it will
not be subjected to extreme temperatures, humidity, or electromagnetic
interference. Specifically, the site you select should meet the following
requirements:
A. The ambient temperature should be between 32 and 104 degrees
Fahrenheit (0 to 40 degrees Celsius).
B. The relative humidity should be less than 90 percent, non-condensing.
C. Surrounding electrical devices should not exceed the electromagnetic
field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.
D. Make sure that the equipment receives adequate ventilation. Do not
block the ventilation holes on each side of the media converter or the
fan exhaust port on the side or rear of the equipment.
E. The power outlet should be within 1.8 meters of the switch.

Connecting the power

1. This Converter is a plug-and-play device.
2. Connect the supplied AC to DC power adaptor with a power voltage
of 7.5Vdc/1.5Amp to the receptacle on the rear panel of the converter,
and then attach the plug into a standard AC outlet with a voltage
range from 100 to 260 Vac.
Sliding Switch
There is a two pin DIP switch on the module which define as switch 1 and switch 2:
on
Sw itch 1 : O n -> Forced M ode
O ff -> A uto N egotiation m ode
Sw itch 2 : O n -> L L R enable
O ff -> L L R disable
1 2