Original declaration of conformity
Solder fume extractor WFE P
We hereby declare that the products described herein
comply with the following guidelines:
2006/42/EG, 2014/30/EU, 2011/65/EU (RoHS)
Applied harmonised standards:
EN 60 335-1: 2012-10
EN 60335-2-45:2012-08;
EN 62233:2008-11/2009-04
EN 55 014-1: 2012-05
EN 55 014-2: 2009-06
EN 61 000-3-2: 2015-03
Error messages and error clearance
Message/symptom
•
Extraction power missing
•
Unit is not running
•
Device does not work
•
Sub-micron paricle becoming dirty to
quickly
EN 61 000-3-3: 2014-03
EN 50 581: 2013-02
Besigheim, 2018-07-05
B.Frühwald
Managing director
Authorised to compile technical documentation.
Weller Tools GmbH
Carl-Benz-Straße 2, 74354 Besigheim, Germany
Possible cause
•
Pipe system leaking
•
Filter is dirty
•
Thermally switched off
•
Fuse is blown
•
Unit is not properly connected
•
Pre-filter has not been used
ENGLISH
T. Fischer
Technical director
Remedial measures
•
Reseal the pipe system
•
change the filter
•
Leave the unit to cool down. Switch on
again after approx. 3 hours.
•
Please contact our Customer Service:
technical-service@weller-tools.com
•
Check the electrical connections
•
Use a pre-filter Fit an M5 filter Use a
preliminary seperator if the
proportion of solid matter is high.
EN