Important Remarks; Important Safety Instructions - Cardin Elettronica SL Serie Manual Del Usuario

Automatización para cancillas correderas con motor de corriente continua
Ocultar thumbs Ver también para SL Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

IMPORTANT REMARKS

READ THE FOLLOWING REMARKS CAREFULLY AND PAY PARTICULAR ATTENTION TO ALL THE
PARAGRAPHS MARKED WITH THE SYMBOL
COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND CREATE DANGER
SITUATIONS FOR THE USERS OF THE SYSTEM. KEEP THESE INSTRUCTIONS FOR FUTURE USE.
• These instructions are aimed at professionally qualified "INSTALLERS OF ELECTRI-
CAL EQUIPMENT" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in which the
installation is situated.
• All maintenance operations must be carried out by professionally qualified technicians.
• This appliance must be used exclusively for the purpose for which it has been made.
"i.e. for the automation of sliding gates" with weights of up to 500 kg and a maxi-
mum travel distance of 12 m.
• The geared motor can be positioned either to the left or to the right of the passage-
way. Any non authorised modifications are to be considered improper and therefore
dangerous.
Caution! The installation of both anti-derailment buffers is
absolutely obligatory.

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road to
eliminate possible traffic disruptions and that the size of the gate, the distance from
the road and the work cycle speed can in no way interfere, causing possible traffic
hazards.
2) The motor must be installed on the inside of the property and not on the public side
of the gate. The gates must not open onto a public area.
3) Manual control switches (including the emergency manoeuvring buttons EMRG1 and
EMRG2) must be installed at a height of between 1,5 and 1,8 m, near enough to the
part that is being guided to be within sight of the operator but far enough away to
be safe from the moving components and in a location not accessible to children.
Controls installed externally must also be protected by a safety device inhibiting
unauthorised use.
4) At least two warning signs (similar to the example on the right) should
be placed, where they can be easily seen by the public, in the area of
the system of automatic operation. One inside the property and one
on the public side of the installation. These signs must be indelible
and not hidden by any objects (such as tree branches, decorative
fencing etc.). If the automation is only to be used for the passage of
vehicles this should be indicated by the presence of two warning signs
forbidding the passage of pedestrians (one inside and one outside the gate). Make
sure that the end-user is aware that children and/or pets must not be allowed to play
within the area of a gate installation. If possible include this in the warning signs
5) The gate operator is designed for use on gates through which vehicles are passing
and may not be fitted with a pedestrian entrance unless it is fitted with controls for
the pedestrian entrance.
6) This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning the use of the appliance
by a person responsible for their safety.
7) A correct earth connection is fundamental in order to guarantee the electrical safety
of the machine
8) Before carrying out any cleaning or maintenance operations make sure the power
is disconnected at the mains, the motor power cables are disconnected and the
batteries have been disconnected.
9) If you have any questions about the safety of the gate operating system, do not install
the operator. Contact your dealer for assistance.
• In order to respect the requirements of the standard EN 12453 (dynamic impact force
limitation) make sure the current sensor is set to SNS1.
Attention! If you use a rubber safety edge (at least 3 cm high) this is obligatory
in order to conform to the standard. If you can't respect the limits, increase
the size of the safety edge or change the type of edge used.
• You are still obliged to check the impact force using the relative instrument.
TECHNICAL DESCRIPTION
• Mains power supply 230 Vac.
• Motor powered with a maximum voltage of 38 Vdc.
• A two-piece shell made of die cast aluminium enclosing the reduction unit
and a pair of steel gears, lubricated with permanently fluid grease.
• The reduction unit stator is made of die cast aluminium and contains worm
gear and a helicoidal crown wheel made of thermoplastic lubricated with
permanently fluid grease.
• The incorporated electronic programmer contains the power stage, the
logic control and the radio receiver decoding module. The power supply is
routed to the electronics card via a separate transformer which is housed
in the same container.
• Cover in shockproof plastic.
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT INSTRUCTIONS
Accessories
106/CRENY
106/CRENY1 - Rack (20 mm x 30 mm) in glass fibre with lower
106/SLOAC
106/SLOAC2 - Rack in galvanised steel (12 mm x 30 mm)
950/XLBS
USER INSTRUCTIONS
Q
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differen-
tial collection site for electronic and electrical goods or to send
it back to the manufacturer if the intention is to replace it with a
new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and will
be dealt with according to the laws and standards of the individual member
nation.
During the opening/closing manoeuvre check for correct operation and activate
WARNING
AUTOMATIC OPENING
the emergency stop button in case of danger. During normal operation wait
KEEP CLEAR
for the gate to open completely before crossing it.
During blackouts with a flat battery the gate can be released and manually
manoeuvred using the supplied release key (see manual release fig. 8). Periodi-
cally check the moving parts for wear and tear and grease if required, using
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
lubricants which maintain their friction levels unaltered throughout time and
are suitable for temperatures of -20 to +70°C.
Eventual repair work must be carried out by specialised personnel using original
spare parts. The appliance is not suitable for continuous operation and may
only be operated using a duty cycle of 70%.
PRELIMINARY CHECKS (fig. 1, page 2)
Before starting the installation make sure that the structure which is to be
automated is in good working order and respects the local standards and
regulations in force.
To this end ensure that:
- The surface of the sliding gate "A" is smooth and has no protrusions up to
a distance of 2.5 m from ground level.
Protrusions on the gate surface which are not greater than 3 mm and have
rounded edges are acceptable.
If the surface of the gate is not smooth, the entire height up to 2.5 m from
the ground must be protected by two of the following devices:
a) photoelectric cells
b) contact safety buffer
- the distance "B" between the fixed parts and sliding parts of the installation
must not exceed 15 mm.
- the runner guide "C", preferably round, should be securely fixed to the
ground, completely exposed and free of any imperfections which could
inhibit the correct movement of the gate.
- when the gate is closed a space of 50 mm "D" must remain for the entire
height of the front part of the gate and a mechanical travel limit "E" must
be positioned on the upper part of the gate.
- The free space "D" can be covered with a rubber anti-crush buffer "F" or
better still a pneumatic or photoelectric contact safety buffer.
- if the gate slides past a fixed structure "G" which has railings or bars leaving
open spaces, it must be protected in one of the following ways:
1. distance "H" greater than 500 mm: no protection required;
2. distance "H" between 500 and 300 mm: wire mesh fencing "I" or punched
metal plating "L" with an opening which does not allow the passage of a
25 mm diameter sphere "M" must be fitted;
14
IMPORTANT REMARKS
- Rack (20 mm x 30 mm) in glass fibre with upper
fastening slits (1 m).
fastening slits (1 m).
- Rack in galvanised steel (22 mm x 22 mm)
2 m to be welded.
1 m with fastening slits.
- Contact safety edge available in lengths of:
1,5 and 3,0 m maximum height 70 mm.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sl524cbSl524

Tabla de contenido