MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION
(A)
MAXIMUM POWER (kW)
POWER SUPPLY CABLE
(Silicone)
BASIN WATER
CONSUMPTION (Indicative)
The data plate is on the side of the appliance (see figure A) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
Attention! This appliance has been produced for use as part of a battery. If used singly, it will be necessary to keep it at
least 10cm away from the adjacent walls.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, norms in force.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
The appliance is supplied without the connection cable.
In the event that it has to be substituted, proceed as follows:
Disconnect the power supply.
- Remove the back panel
- Disconnect the cable from the junction-box situated at the back.
- Loosen the cable blocker and pull out the cable..
- Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in the
junction box and fix them into place.
- Block the cable with the cable blocker, and reassemble the back panel. The earth wire must be longer than the others
so that if the cable blocker should break, it will disconnect after the tension wires.
N.B. The connection cable must have the following characteristics: it must be at least type H05 RN-F (resistant to
a temperature of at least 150°), and must have an adequate section for the power of the appliance (see technical
data table).
GB
TECHNICAL DATA TABLE
CWK-94ET
40x90x90h
~
400V
3N 50/60 Hz 400V
7,8
5,415
5x1,5 mm²
1 lt/h
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
IE
CWK-98ET
CWKT-94ET
80x90x90h
40x90x29h
~
~
3N 50/60 Hz 400V
3N 50/60 Hz 400V
15,63
7,8
10,83
5,415
5x2,5 mm²
5x1,5 mm²
1 lt/h
1 lt/h
20
CWKT-98ET
80x90x29h
~
3N 50/60 Hz
15,63
10,83
5x2,5 mm²
1 lt/h