Machine Information; Technical Specifications; Residual Risks - Ferm CDM1108S Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
b) Use power tools only with specifically
designated battery packs. Use of any other
battery packs may create a risk of injury and fire.
c) When battery pack is not in use, keep it
away from other metal objects, like paper
clips, coins, keys, nails, screws or other
small metal objects, that can make a
connection from one terminal to another.
Shorting the battery terminals together may
cause burns or a fire.
d) Under abusive conditions, liquid may be
ejected from the battery; avoid contact.
If contact accidentally occurs, flush with
water. If liquid contacts eyes, additionally
seek medical help. Liquid ejected from the
battery may cause irritation or burns.
Service
a) Have your power tool serviced by a
qualified repair person using only identical
replacement parts. This will ensure that the
safety of the power tool is maintained.
For the charger
Intended use
Charge only 3.6V max.1.3Ah Li-ion type
rechargeable battery packs. Other types of
batteries may burst causing personal injury and
damage.
a) The appliance is not to be used by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they
have been given supervision or instruction
b) Children being supervised not to play with
the appliance
c) Do not recharging non-rechargeable batteries!
d) During charging, batteries must be placed in
the well ventilated area!
Power cord replacement
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.

Residual risks

Even when the power tool is used as
prescribed it is not possible to eliminate all
residual risk factors. The following hazards
6
may arise in connection with the power tool's
construction and design:
a) Health defects resulting from vibration
emission if the power tool is being used
over longer period of time or not adequately
managed and properly maintained.
b) Injuries and damage to property to due to
broken accessories that are suddenly dashed.
Warning! This power tool produces an
electromagnetic field during operation.
This field may under some circumstances
interfere with active or passive medical
implants. To reduce the risk of serious or
fatal injury, we recommend persons with
medical implants to consult their
physician and the medical implant
manufacturer before operating this
power tool.

2. MACHINE INFORMATION

Intended use
This screw driver is intended for driving in and
loosening screws

Technical specifications

Model No
Charger
Input of charger
Output of charger
Rechargeable battery
Battery charging time
Chuck capacity
No load speed
Weight (incl. battery)
Sound pressure level L
PA
Sound power level L
WA
Hand-arm vibration a
h
(screw driving without impact)
Vibration level
The vibration emission level stated in this
instruction manual has been measured in
accordance with a standardized test given in
EN60745; it may be used to compare one tool
CDM1108S
CDA1078S
100-240V~ 50/60Hz 0.2A
5V d.c. 1A
3,6 V
Li-ion 1.3 Ah
2-3 hours
¼" hex
180 /min
0.345kg
53.63 dB(A) K= 3 dB(A)
64.63 dB(A), K=3dB(A)
1.119 m/s
K=1.5 m/s
2
2

Publicidad

Tabla de contenido
loading

Tabla de contenido