Technical Specifications; Electrical Wiring - Caterlite GG769 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Troubleshooting
If your CATERLITE appliance develops a fault, please check the following table before making a call to
the Helpline.
Fault
The appliance is not
working
"E02" on Display

Technical Specifications

Model
Voltage
GG769
230V
50Hz

Electrical Wiring

This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit. If in doubt consult a qualified
electrician. Electrical isolation points must be kept clear of any obstructions. In the event of any
emergency disconnection being required they must be readily accessible.
Probable Cause
The appliance is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Unsuitable cookware
Appliance has overheated
Power
Current
(max.)
1800 W
7.5 A
Action
Check the appliance is plugged in
correctly and switched on
Call CATERLITE agent or qualified
technician
Replace the plug fuse
Check power supply
Replace with suitable cookware
Allow to cool for 10 min before
restarting.
Power
Temperature
range
range
500
60-240°C
-1800W
UK
Dimensions (h
Weight
x w x d) mm
(kg)
85 x 386 x 328
5.6 kg

Publicidad

Tabla de contenido
loading