INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
During installation, follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA).
This pump is supplied with a grounding conductor and/or grounding-
type attachment plug. To reduce the risk of electric shock, ensure
that it is connected to a properly-grounded, grounding-type
receptacle. Do not remove the third prong from the plug.
For maximum safety, this pump should be connected to a three-
prong grounded outlet equipped with a ground fault circuit
interrupter (GFCI) device.
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Pump should only be used with
liquids compatible with pump component materials. Do not use
in explosive atmospheres or hazardous locations as classified by
the NEC, ANSI/NFPA70. Failure to follow this warning can result
in property damage, personal injury, or death.
Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water. Failure to follow
this warning can result in fatal electrical shock.
Make certain that the unit is disconnected from the power source
before attempting to service or remove any component. If the
power disconnect is out-of-sight, lock it in the open position and
tag it to prevent unexpected application of power.
Periodically inspect pump and system components. Regularly
check hoses for weakness or wear, making certain that all
connections are secure. Perform routine maintenance as required
and in accordance with the Service Instructions section.
In any installations where property damage and/or personal injury
might result from an inoperative or leaking pump due to power
outages, discharge line blockage, or any other reason, a backup
system(s) and/or alarm should be used.
Model • Modèle • Modelo
VCC-20S
VCC-20ULS
CAREFULLY
BEFORE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
Support pump and piping when assembling and when installed.
Failure to do so may cause piping to break, pump to fail, motor
bearing failures, etc.
DESCRIPTION
This Little Giant condensate pump automatically removes water
that drips from an air conditioner evaporative coil. The pump is
controlled by a float/switch mechanism, which turns on the pump
when approximately 1" of water collects in its tank, and turns off the
pump when the water in the tank drains to approximately 1/2".
INSTALLATION
1. Before installing pump, allow air conditioner to cycle several
times, collecting condensate in a separate container to help
flush any residual oils that may remain in the system.
2. Carefully unpack the pump. Remove the cardboard packing
from the motor cover air slots. Carefully slide the packing
away from the pump. This packing is used to prevent switch
movement during shipment.
3. Mounting the pump: The tank has two slots provided to mount
the unit (Figure 1). The slots are located on the end of the tank
cover. The unit should be mounted either on the side of the
air conditioner unit or nearby wall. Pump must be level and
the inlet must be below the coil drain. Conduit fittings are not
compatible with the plastic pump housing.
4. The pump should not be installed in a manner that will subject
it to splashing or spraying.
Figure 1
Figure 2
Figure 3
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant VCC-20S

  • Página 1 Support pump and piping when assembling and when installed. VCC-20S Failure to do so may cause piping to break, pump to fail, motor bearing failures, etc. VCC-20ULS Franklin Electric Co., Inc. DESCRIPTION P. O. Box 12010 This Little Giant condensate pump automatically removes water Oklahoma City, OK 73157-2010 405.947.2511 •...
  • Página 2: Electrical Connections

    ELECTRICAL CONNECTIONS 1. Be sure the floats move freely. Clean as necessary. 2. Remove the volute and check for obstructions. Clean as necessary. 1. Shut off electrical power at fuse box before making any 3. Clean the tank with warm water and mild soap. connections.
  • Página 3: Directives De Securite

    4. Si une prise avec fusible est utilisée sous une tension de 230 DIRECTIVES DE SECURITE V, l’utilisation d’un fusible de 1 ampère est recommandée. TUYAUTERIE NE PAS UTILISER POUR POMPER DES LIQUIDES EXPLOSIFS 1. Faire sortir un tube isolant souple ou un tuyau de l’évaporateur OU INFLAMMABLES (ESSENCE, HUILE, KÉROSÈNE, ETC.) et le brancher dans l’arrivée de la pompe.
  • Página 4: Introducción

    del motor. Retire el embalaje de la bomba, haciéndolo INTRODUCCIÓN deslizar cuidadosamente. Este embalaje se usa para evitar el movimiento de los interruptores durante el transporte. Su bomba de condensación Little Giant está diseñada como una bomba de remoción de condensación automática para remover 3.
  • Página 5: Comprobacion

    COMPROBACION continuamente, sin impulsar el agua a la altura total de la tubería de descarga. En este caso, se recomienda que el 1. Conecte la electricidad. adaptador de 1/4 de pulgada que se suministra, se utilice 2. Quite el conjunto del motor y la cubierta del tanque y con una tubería de un diámetro interno de 1/4 de pulgada.
  • Página 6 Figure 6 Item Part No. Description 154006 Cover, Motor 154031 979554 Motor, 115V 979555 Motor, 230V 154021 Plate, Motor 154055 Bracket, Switch 950337 Switch, VC Pump 950403 Wire Nut 902436 Screw, 8-18 x 1/2" 154038 Strain Relief 951604 Wiring Harness, 115V 951606 Wiring Harness, 230V 951089...
  • Página 7: Garantie Limitée

    LIMITED WARRANTY Tous les produits garantis retournés feront l’objet d’une inspection complète afin de déterminer si la défectuosité est couverte par Your Little Giant product is guaranteed to be in perfect condition la garantie. Little Giant va honorer la garantie dans la période de when it leaves our Factory.
  • Página 8 Para la ayuda técnica, por favor póngase en contacto ....1.888.956.0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 993554 - 05/2008 ©2008 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Este manual también es adecuado para:

Little giant vcc-20uls

Tabla de contenido