H
OW INSTALL SER WITH ELECTROBRAKE
IMPORTANT: Before install SER check that the shutter is correctly balanced by its screws mounted on the shaft. Verify it manually by opening
and closing the shutter.
Spring housing
Shaft
SER 20
SER 22-22 S
SER 24
After have choosen SER according to the dimensions of the shutter, verify
the diameter of the spring housing and of the shaft, because they must
have the same diameter of the choosen motor.
If they're different use the required adaptor:
SPRING HOUSING ADAPTER Ø 220
SHAFT ADAPTER Ø 42/48
SHAFT ADAPTER Ø 42/60
SHAFT ADAPTER Ø 48/60
A - Make the holes on the shaft as indicated on the rising above draw (see
pict. 1), open the motor and mount it as indicated in the instruction.
B - Open the pulley unscrewing the 2 screws (1).
C - Dismount the fixing flange on the shaft unscrewing the screws (2).
D - Mount SER on the shaft and position the motor up and the limit switch
down (see pict. 3). Fix SER on the shaft using the fixing flange and its
screws (2) and (3).
E - Reassemble the pulley and re-screw its screws (1).
F - On the last section of the shutters make a hole Ø 12 mm / 0,4 in which
allows to fix the shutter to the pulley of SER using the proper screws
(4).
G - Insert the electrical cable and the releasing cable in the holes on the
shaft and execute the electrical connections.
Hole diam. 12 mm / 0,4 in (entry of electric cable)
6-1624000 REV. 09 DEL 05/03/13
Hole Ø 12 mm / 0,4 in (in vertical) (only for the cable of the brake)
Ø 200 mm/7,8 in Ø 48 mm/1,8 in
Ø 220 mm/8,6 in Ø 60 mm/2,3 in
Ø 240 mm/9,4 in Ø 76 mm/2,9 in
=
code 64100206
code 64100203
code 64100204
code 64100205
Hole Ø 12 mm / 0,4 in (entry of the release cable)
=
45
250
200
Hole Ø 12 mm / 0,4 in (frontal-seethrough)
IMPORTANT
Respect the radius of the curve (at least 15 cm / 5,9 in)
Electrobrake
Electric Cable
15
15
Hole Ø 12 mm / 0,4 in (frontal)
=
=
Release Knob
G
B
1
2
3