Trimmer SLOW.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during
different slow-down phases; if said force becomes greater than the adjusted level, the system intervenes by inver-
ting the direction of movement.
Trimmer A.C.T. = Adjusts the waiting time in the opening position. Once this time frame has lapsed, an automatic
closing procedure is performed. The waiting time may be adjusted to between 1 second and 120 seconds. Adjusting
to the minimum excludes the automatic closing function.
Trimmer CL.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during movement closing; if
said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.
Trimmer OP.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during movement opening; if
said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.
Function selection
1 ON - Activates the procedure for adjusting the opening and closing endpoints and the procedure for programming the decelerated
opening.
2 ON - Activates the procedure for adjusting the partial opening and the procedure for programming the decelerated endpoint closing.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.