9.2 Settings
• Emissivity: default emissivity is 0.95
• To change emissivity: press "MODE" until the bottom left shows the "E" sym-
bol with two arrows pointing up and down. Press the up and down buttons to
adjust the emissivity. Emissivity range: 0.1-1.0.
• Memory: To save readings: press "MODE" until "MEM" appears in the bot-
tom left comer of the display. Press the trigger to save the displayed reading.
• To recall saved readings: press "MODE" until "RCL" appears in the bottom
left corner of the display. Use the up and down buttons to scroll through the
saved readings.
• To clear all saved readings press "MODE" until "CLR ALL" appears on the
bottom of the display. Press the trigger to clear readings.
• To show the maximum recorded value: press "MODE" until "MAX" on the
bottom left corner of the display.
• To show the minimum recorded value: press "MODE" until "MIN" appears on
the bottom left corner of the display.
• To show the difference between the minimum and maximum values: press
"MODE" until "DIF" appears on the bottom left corner of the display.
• To show the average recorded value: press "MODE" until "AVG" appears on
the bottom left corner of the display.
• To set the high alarm level: press "MODE" until "HAL" appears on the bottom
left corner of the display. Press the up and down buttons to set the alarm
level.
• To set the low alarm level: press "MODE" until "LAL" appears on the bottom
left corner of the display. Press the up and down buttons to set the alarm
level.
• When the high and low alarms are set, the meter will beep if the temperature
measured is above the high level or below the low level. In addition, the main
display will show "Hi" or "Lo" and the icon in the top right corner will turn red
or blue to indicate high or low alarm respectively.
• To measure temperature using the included type-k thermocouple probe:
press "MODE" until "PRB" appears on the bottom left corner of the display.
Insert the type-k thermocouple into the thermocouple jack of the bottom of
the thermometer.
• Make sure to observe the polarity when inserting the thermocouple. Touch