RIGHT
NOTICE :
The product warranty will be void if the installation and operation are not performed as per our instruction manual. Please read the
enclosed manuals carefully before operating the units.
Subject to technical modifi cation!
Open screws
Cover
Hose connection
Roue
Power turbine
Flaps
LEFT
english
3. Trouble shooting:
Cleaner moves to slowly:
+) Back wash and clean the fi lter
system, the baskets of the pump and
skimmers.
+) Close all valves, leaving only the
suction line to cleaner open
Cleaner moves to fast or climbs out of the water:
+) Partially open another suction line,
skimmer or main drain.
+) install a safety bypass valve (designed
specifi cally for OCEAN VAC).
A far corner of your pool is not cleaned:
+) Vaccum hose is to short (add. additi-
onal lengths of hose available in your
nearest pool store)
Vacuum hose curls up:
+) Check the swivel hose adapter on the
cleaner to insure free turning.
+) Wrong storage ? Straighten the hose
Steering cam
by laying it out straight in the sun for
a few hours. Water return may need to
Power turbine
be directed downward.
Wheels do not turn:
+) Turbine is blocked by a branch or
object. TURN PUMP OFF!!
+) Remove visible
debris. Verify free passage by turning
the right wheel forward.
Safety valve