Maintenance
Maintenance Tips
%H VXUH WR FOHDQ WKH DLU ¿OWHU HYHU\ ZHHNV IRU RSWLPDO SHUIRUPDQFH
-The water collection tray should be drained immediately after P1
error occurs, and before storage to prevent mold.
-In households with animals, you will have to periodically wipe down
WKH JULOO WR SUHYHQW EORFNHG DLUÀRZ GXH WR DQLPDO KDLU
Clean the Unit
Clean the unit using a damp, lint-free cloth and mild
detergent. Dry the unit with a dry, lint-free cloth.
Store the unit when not in use
-Drain the unit's water collection tray according to the instructions in
the following section.
Faults Diagnosis
Please check the machine according to the following form before asking for maintenance:
Problem
Unit does not turn
on when pressing
button
ON/OFF
Unit does not cool
well
The unit is noisy
and vibrates too
much
The unit makes a
gurgling sound
Possible Cause
P1 Error Code
In COOL mode: room
temperature is lower than
the set temperature
7KH DLU ¿OWHU LV EORFNHG ZLWK
dust or animal hair
Exhaust hose is not
connected or is blocked
The unit is low on
refrigerant
Temperature setting is too
high
The windows and doors in
the room are open
The room area is too large
There are heat sources
inside the room
The ground is not level
7KH DLU ¿OWHU LV EORFNHG ZLWK
dust or animal hair
This sound is caused by the
ÀRZ RI UHIULJHUDQW LQVLGH
the unit
-Run the appliance on FAN mode for 12 hours in a warm room to
dry it and prevent mold.
-Turn off the appliance and unplug it.
&OHDQ WKH DLU ¿OWHU DFFRUGLQJ WR WKH LQVWUXFWLRQV LQ WKH SUHYLRXV
VHFWLRQ 5HLQVWDOO WKH FOHDQ GU\ ¿OWHU EHIRUH VWRULQJ
-Remove the batteries from the remote control.
Be sure to store the unit in a cool, dark place. Exposure to direct
sunshine or extreme heat can shorten the lifespan of the unit.
NOTE: The cabinet and front may be dusted with an oil-free
cloth or washed with a cloth dampened in a solution of
warm water and mildliquid dishwashing detergent. Rinse
thoroughly and wipe dry. Never use harsh cleansers, wax
or polish on the cabinet front. Be sure to wring excess
water from the cloth before wiping around the controls.
Excess water in or around the controls may cause
damage to the unit.
Troubleshooting
The Water Collection Tray is full.
Turn off the unit, drain the water
from the Water Collection Tray
and restart the unit.
Reset the temperature
Turn off the unit and clean the
¿OWHU DFFRUGLQJ WR LQVWUXFWLRQV
Turn off the unit, disconnect the
hose, check for blockage and
reconnect the hose
Call a service technician to inspect
the unit and top off refrigerant
Decrease the set temperature
Make sure all windows and doors
are closed
Double-check the cooling area
Remove the heat sources if
possible
3ODFH WKH XQLW RQ D ÀDW OHYHO
surface
Turn off the unit and clean the
¿OWHU DFFRUGLQJ WR LQVWUXFWLRQV
This is normal
42