Table Of Programming Parameters - V2 SPA HYPERFOR-I Manual Del Usario

Motor electromecanico irreversibles 230v trifasico con inverter para puertas correderas hasta 4000 kg de peso
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

22.6 - TABLE OF PROGRAMMING PARAMETERS

PARAMETER
VALUE
MODE
STAN
PRES
S.PRE
OROL
DIR
DX
SX
P.APP
0-100%
T.PRE
0.5"-10.0"
NO
T.PCH
0.5"-10.0"
NO
POT
30-100%
VEL
5-99HZ
VEL.R
5-99HZ
SPUN
0-30%
ACCEL
0-6
DECEL
0-6
FRENO
0-10
RAL.A
0-50%
RAL.C
0-50%
VEL.M
5-99HZ
ST.AP
PAUS
CHIU
NO
ST.CH
STOP
APRE
ST.PA
CHIU
NO
PAUS
SUBMENU
DESCRIPTION
Working mode
Standard
Dead man
Mixed
Timer
Gate direction (the direction you see from
the inside)
The gate opens rightwards
The gate opens leftwards
Partial opening
Pre-blinking time before opening
Function disabled
Pre-blinking time before closing
Pre-flashing during closing equal to T.PRE
Motor power
Normal speed
Slowed speed
Over voltage at start opening
Starting ramp
Slowing ramp
Brake intensity
Slowed opening run
Slowed closing run
Speed in manual operation
Start during the opening phase
The gate stops and pauses
The gate immediately starts closing
The gate continues to open (the command is
ignored)
Start during the closing phase
The gate stops and the cycle is considered as
complete
The gate re-opens
Start during pause
The gate starts closing
This command is ignored
The pause time is reset
- 56 -
DEFAULT
CHAPTER
MEMO
18
STAN
DX
50%
13
1.0"
13
NO
9
100
9
50
9
25
9
0
9
2
9
2
9
4
9
10%
9
10%
19
30
16
PAUS
16
STOP
16
CHIU

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hyperfor 4000-i-m4

Tabla de contenido