INSTRUCTIONS MANUAL
Plastic lamp with integrated PIR sensor and LED lamp
C-LOGIC 685-MD
SKU: CLOGIC685MDDUALCBINT
ENGLISH
The product is an energy-saving automatic sensor lamp, adopting integrated circuit and pre-
cise detecting components. It gathers automatism, convenience, safety, saving-energy and
practical functions. Its performance is stable. It can identify day and night. The lamp can turn
on when one enters detection
and can turn
after a time delay.
SPECIFICATION:
• Power Source: 110-240V~
• Detection Range: 160° (wall) / 360º (ceiling)
• Power Frequency: 50/60Hz
• Detection Distance:
- Wall: Máx. 9m(<24ºC)
- Ceiling: Máx. 6m (<24ºC)
• Ambient Light: <3-2000LUX (adjustable)
• Working Temperature: -20~+40ºC
• Working Humidity: <93%RH
• Time Delay:
- Min.10sec±3sec
- Max.5min±1sec
• Rated Load:
- 15W (1250lm)
• Detection Moving Speed: 0.6-1.5m/s
• Installation Height: 1.8 - 2.5m (wall) / 2.2 - 4m (ceiling)
• Degree of protection IP44
• Color temperature: 4.000K
FUNCTION:
• Can identify day and night: The consumer can adjust working state in
light. It can work in the daytime and at night when it is adjusted on the "sun" position (max).
It can work in the ambient light less than 3LUX when it is adjusted on the "moon" position
(min). As for the adjustment pattern, please refer to the testing pattern.
• Time-Delay is added continually: When it receives the second induction signals within the
induction, it will restart to time from the moment.
• Adjustable Time Delay: the length of time delay could be set according to the customers'
requirement, the minimum time of this item is 10sec ± 3sec, the maximum is 5min±1sec.
INSTALLATION ADVICE:
• Switch
the power.
• Unscrew the plastic screw nut and remove the glass lampshade.
• Pass the wire through the hole in the bottom and connect the power wire into connection-
wire column according to the connection-wire diagram. Install the sensor lamp in the
position where you need with
• Install back the lampshade, then electrify and test it.
TEST:
• Turn the TIME knob anti-clockwise on the minimum. Turn the LUX knob clockwise on the
maximum (sun).
• Switch on the power; the lamp will have no signal at the beginning. After Warm-up 30sec,
the lamp can start work .If it receives the induction signal, the lamp will turn on. While there
is no another induction signal any more, the lamp should stop working within 10sec±3sec.
• Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than
3LUX, the lamp should not work. If you cover the detection window with the opaque
objects (towel etc), the lamp would work .Under no induction signal condition, the lamp
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
the sensor lamp could not work!
• Should be installed by electrician or experienced person.
• Avoid installing it on the uneven object.
• There should be no hindrance and moving objects in front of the detection windows to
detection.
• Avoid installing it near air temperature alteration zones such as air condition, central
heating, etc.
• Considering your safety, please do not open the cover when you
installation.
SOME PROBLEM AND SOLVED WAY:
• The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
• The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to
ceive the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection
d. Please check if the installation height corresponds to the height showed in the instruction.
e. Please check if the moving orientation is correct.
automatically when one leaves detection
screws.
(SUN) position, otherwise
the hitch after
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection
d. Please check if the installation height corresponds to the height showed in the instruction.
e. Please check if the moving orientation is correct.
• The sensor can not shut
a. Please check if there is continual signal in the detection
b. Please check if the time delay is the longest.
c. Please check if the power corresponds to the instruction.
SENSITIVITY
EN
MOUNTING
CONNECTION-WIRE DIAGRAM
ambient
TEST
FULL MANUAL DOWNLOAD
MANUFACTURER:
MGL International
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
to re-
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
the load automatically:
You can download the complete manual at the
URL
https://clogic-intl.com/clogic-685-md
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast: 760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com