Troubleshooting (continued)
Problem
Burner will not light
using ignitor.
Burner will not match
light.
Sudden drop in gas
flow or low flame.
Flames blow out.
Flare-up.
Persistent grease fire.
Flashback...
(fire in burner ).
Unable to fill LP
cylinder.
Cooking slower than
expected
18
Possible Cause
• Rotary knob rotates without clicking.
• Sparking between ignitor and electrode.
• See "GAS ISSUES:" on previous page.
• Match will not reach.
• Improper method of match-lighting.
• Out of gas.
• Excess flow valve on regulator tripped.
• Vapor lock at coupling nut/LP cylinder
connection.
• Low on LP gas.
• Excess flow valve tripped.
• Grease buildup.
• Excessive fat in meat.
• Excessive cooking temperature.
• Grease trapped by food buildup around
burner system.
• Burner is blocked.
• Some dealers have older fill nozzles
with worn threads.
• Vapor Lock
• Valve not properly aligned to burner
• High wind conditions
Prevention/Solution
• Replace knob.
• Inspect wire insulation and proper connection. Replace wire if
insulation is broken.
• Use long-stem match (fireplace match).
• See "Match-Lighting" section of Use and Care.
• Check for gas in LP cylinder.
• Turn off control knob, wait 30 seconds and light appliance. If flames
are still low, turn off knob and LP cylinder valve. Disconnect
regulator. Reconnect regulator and leak-test. Turn on LP cylinder
valve, wait 30 seconds and then light appliance.
• Turn off knob and LP cylinder valve. Disconnect coupling nut from
cylinder. Reconnect and retry.
• Refill LP cylinder.
• Refer to "Sudden drop in gas flow" above.
• Clean burner and inside of fryer body.
• Trim fat from meat before grilling.
• Adjust (lower) temperature accordingly.
• Turn knob to OFF. Turn gas off at LP cylinder. Let fire burn out. After
fryer cools, remove and clean all parts.
• Turn knob to OFF. Clean burner. See burner cleaning section of Use
and Care.
• The worn nozzles don't have enough "bite" to engage the valve. Try
a second LP dealer.
• Turn off control knob and disconnect coupling nut from LP cylinder.
Reconnect and retry.
• Loosen control panel and valve. Be sure valve is centered top to
bottom and left to right in burner . Tighten all components once
proper alignment is achieved.
• Relocate the appliance to a less windy area. Use Top Cover during
cooking.

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido