F
UNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open command, regardless
the position of the boom arm. If the OPEN1 button is pressed
during the closing, the boom arm stops and will reverse the
movement in opening. In PARK MODE (DIP6 ON), if there is
a vehicle at the entry (see scheme 4) and the TLC contact is
closed, the OPEN1 command opens the barrier. Otherwise,
if the TLC contact is open the OPEN1 command is disabled.
CLOCK FUNCTION
If you want the Clock Function must request PARK 230V
with firmware 04.
ATTENTION: A CLOCK CONNECTED TO PARK 230V with
fw 05 or more ACTIVATES THE OPENING MOVEMENT OF
THE BARRIER WITHOUT HAVING THE PROTECTION OF
THE SAFETY DEVICES!
The Clock Function permits to keep the boom arm opened
even if, for example, the Automatic Closing is enabled (DIP3
ON) or somebody commands the barrier closing. It is useful
during rush hour, when traffic is heavy and the flow is low (e.g.
entrance/exit of employees, emergencies in residential areas
or car parks) and it's necessary to keep the boom arm opened.
CLOCK FUNCTION APPLICATION
It is necessary to request a PARK 230V control panel with
firmware 04.
It can be done by connecting a switch and/or a daily/weekly
timer either in parallel to the OPEN1 button or instead of the
OPEN1 button. When the control board receives this command,
the boom arm will open and by keeping this contact closed for
all the time of the boom arm opening, the Clock Function is
automatically activated. In fact, once reached the open position,
the barrier will remain opened and all of the control board
features are blocked. Only when the OPEN1 button is released,
the control board functions are re-activated and the boom arm
will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command, regardless the position of the boom arm.
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-close-stop-open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
O
PERATING IN PARK MODE (DIP6 ON)
TO ENTER:
Provided there be a vehicle on the Entry magnetic loop
(see scheme 4), opening can be controlled by pressing
OPEN1, K BUTT or RADIO switch (OPEN1 performs the
boom arm opening only if the TLC, connected to the Entry
Magnetic Loop, contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic loop (see
scheme 4), opening can be controlled by pressing OPEN2,
K BUTT, RADIO switch. The OPEN2 can be connected to
the Exit magnetic loop.
If the DIP8 is turned ON, the OPEN2 will perform the
barrier opening regardless the presence of a vehicle at
the Entry.
If the DIP8 is turned OFF, the OPEN2 will perform the
barrier opening if there is no vehicle on the magnetic
sensor connected to the TLC input (TLC contact opened).
In both the conditions, TO ENTER and TO EXIT, from the
complete boom arm open position:
If the Automatic Closing is enabled (DIP3 ON),
the boom arm will close at the end of the delay time
programmed (see Point C).
If the Automatic Closing is disabled, the boom arm
will remain open until a closing command is pressed or
until the vehicle passes in front of the photocells, giving an
OK CLOSE impulse to the control board (the OK CLOSE
command can be connected to the NO contact of the
photocell receiver).
OPEN2 BUTTON (COM - OPEN2) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the
OPEN2 command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OPEN2 will perform the boom arm opening
+
K BUTTON
LED
R=2K2
STOP
CLOSE
+
OPEN 1
LSC
LSO
TIMER
AERIAL
+
+
BUZZER
K BUTTON
LED
R=2K2
-
STOP
CLOSE
+
OPEN 1
12 Vdc max 0,5A for ACCESSORY SUPPLY
12 Vdc max 0,5A for AUTOTEST EDGE
31
31
AERIAL
+
COAX
BUZZER
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command open-stop-close-stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled turning ON the DIP3. The
maximum time that can be programmed is 5 minutes (see Point D).
COAX
_
+
_
+
depending on the switch DIP8 position.
If DIP8 is turned ON and PARK MODE is enabled, OPEN2 will perform the boom arm
opening regardless the state of the TLC input.
STANDARD OPERATION
DIP 6 OFF
ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT
PARK OPERATION
DIP 6 ON
MAGNETIC LOOP
TO ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D+
D+
MAGNETIC LOOP
TO EXIT
G
B