Safety Instructions; General Instructions; Electrical Safety - Desoutter MULTICVIL II Serie Inicio Rápido

Tabla de contenido

Publicidad

6159933490
Issue no: 01
Original instructions.
© COPYRIGHT 2010, DESOUTTER HP2
7BW UK
All rights reserved. Any unauthorized use
or copying of the contents or part thereof
is prohibited. This applies in particular to
trademarks, model denominations, part numbers
and drawings. Use only authorized parts. Any
damage or malfunction caused by the use of
unauthorised parts is not covered by Warranty or
Product Liability.
DECLARATION OF USE
MULTICVIL II system is designed to drive 2 to 32
multi spindle machine.
It consists of several CVIL II S modules
according to the number of connected tools
and a CVIL II M module to provide the interface
between the PLC, the PC and the slave
modules.
Although it is possible to connect any tool of
the range, portable and fixture tools (ER; ERA;
EME), this equipment is mainly dedicated to
fixture tools.
The CVI II M is the system intelligence: it fully
controls the tightening sequence, centralises the
controls and controls the CVIL II S modules.
The CVIL II M module doesn't drive any tool.
No other use permitted.
For professional use only.
EMC restriction of use: for industrial use only.
DATA
(See page 3).
● Weigh: 5.9kg
● Mains voltage: 115VAC / 230VAC ± 10%
50/60Hz (automatic switching).
● Power CVIL II M: 20 W
● Power CVIC II S: 0,65 kW

SAFETY INSTRUCTIONS

General instructions

To reduce risk of injury, everyone
using, installing, repairing, maintaining,
changing accessories on, or working
near this tool must read and understand
the safety instructions before performing
any such task. Failure to follow all
instructions listed below may result
in electric shock, fire and/or serious
personal injury.
12 / 96
Caution: risk of explosion if battery is
replaced by an incorrect type. Dispose
of used batteries according to the
instruction.
General safety instructions are collected
in the 6159931790 tool safety booklet
and this manual.
Save these instructions carefully.
This symbol means:
Caution, risk of electric shock.

Electrical safety

Earthing connection
WARNING: this power tool must be
earthed.
They must be installed and grounded in
accordance with all relevant codes and
ordinances.
Never remove the grounding prong or modify the
plug in any way.
Do not use any adaptor plugs.
Check with a qualified electrician if you are
in doubt as to whether the outlet is properly
grounded.
If the tools should electrically malfunction
or break down, grounding provides a low
resistance path to carry electricity away from
user.
The controller has a thermal protection and
a protection by means of over current and
differential circuit breaker.
Never replace the circuit breaker by a
model of higher value.
Never replace the circuit breaker by
short-circuit.
Circuit breaker characteristics:
● Voltage: 230V
● Max current: 16A
● Curve: D
● Differential sensitivity: 30mA
Differential circuit breaker
The controller is equipped with a differential
circuit breaker to protect the operator from
electric shock.
A differential circuit breaker in the power supply
to the controller detects any insulation defect
between the phases of the network and the
earth and immediately cuts off the power supply.
06/2010

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cvil ii sCvil ii m61593268306159326820

Tabla de contenido