Bosch MMD 540H Manual De Instrucciones página 29

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

28 | MMD 540H Hybrid Multimeter | Electrical Specifi cations
DC Current
Range
40.00mA
400.0mA
20A
Overload Protection: 0.5A / 250V and 20A / 250V Fuse.
Maximum Input: 400mA dc or 400mA ac rms on uA / mA ranges,20A dc or
ac rms on 20A range.
AC Current
Range
40.00mA
400.0mA
20A
Overload Protection: 0.5A / 250V and 20A / 250V Fuse.
Frequency Range: 50 to 60 Hz
Maximum Input: 400mA dc or 400mA ac rms on uA / mA ranges, 20A dc or
ac rms on 20A range.
Resistance
Range
400.0Ω
4.000kΩ
40.00kΩ
400.0kΩ
4.000MΩ
40.00MΩ
Capacitance
Range
4.000nF
40.00nF
400.0nF
4.000uF
40.00uF
400.0uF
4.000mF
40.00mF
Robert Bosch LLC
Resolution
10uA
100uA
10mA
Resolution
10uA
100uA
10mA
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
1pF
10pF
0.1nF
1nF
10nF
0.1uF
0.001mF
10.00mF
MMD 540H Instruction Manual | Version 1 | February 2008
Accuracy
±1.5% of rdg ±3 dgts
±2.5% of rdg ±5 dgts
Accuracy
±1.8% of rdg ±5 dgts
±3.0% of rdg ±7 dgts
Accuracy
±1.2% of rdg ±4 dgts
±1.0% of rdg ±2 dgts
±1.2% of rdg ±2 dgts
±2.0% of rdg ±3 dgts
Accuracy
±5.0% of rdg±50 dgts
±5.0% of rdg ±7 dgts
±3.0% of rdg ±5 dgts
±10% of rdg ±10 dgts

Publicidad

Tabla de contenido
loading

Tabla de contenido