INSTRUCTIONS
MODEL: SV3002
SV3003
Before using or installing the product, kindly read the instructions and follow safety rule.
Installation should be provided by qualified person/company.
Thank you for choosing the item of company PANLUX s.r.o.
Technical data
Notice
Input voltage: 230V~50Hz
Before using, check the product and make sure there is no damage, otherwise
Load: max. 1200W
do not use it. Before any manipulation assure that mains electrical supply is
Supply in standby mode: < 0,9W
disconnected. In case of damage do not repair or disassemble the product.
Transmission power: SV3002 >10mW
For the best functional results, move toward the sensor. The incorrect function
SV3003 <10mW
of the product can be caused by interruption of electromagnetic field, small
Current: max. 5,2A
temperature difference between moving object and surroundings, reflection
Protection: IP20
(e.g. strong luminous source). With regard to a wide sortiment and development
Class of protection: II.
in electronical components, it is impossible to ensure correct function for all
Material: plastic PC
ballasts, starters and lighting sources. Kindly use these sensors with PANLUX products.
Angle of detection: horizontal - 360°
vertical - 160°
Reach: SV3002 - radius 2-8m (±10%), fluent setting, logarithmic scale
SV3003 - radius 2-10m (±10%), 3 default values (2m | 5m | 10m)
Time setting: SV3002 - 8s (±5s) to 12 min (±30s), fluent setting, logarithmic scale
SV3003 - 12s (±3s) to 30min (±3min), 4 default values (12s | 3min | 15min | 30min)
Twilight setting: SV3002 - 2-2000lux (±5%), fluent setting, logarithmic scale
SV3003 - 10-2000lux (±10%), 4 default values (10lx | 100lx | 500lx | 2000lx)
Location: interiors
Recommended installation height: 2,5m
Operating temperature: -10°C~+50°C
Dimensions: 98x85x90mm
Weight: 67g
Installation
connect N, L with power
connect N, L´ with load (lighting fixture)
2
main supply cable
load
L
L'
N
1
L
N
3
L´
Principle of sensor
The integrated HF sensor emits high-frequency electromagnetic waves (5,8GHz) and receives the echo. The sensor
etects the change in echo from even the slightest movement in the lamps´ detection zone. A microprocessor
then triggers the switch in lamp ON. Detection is possible through doors, panels of glass or thin walls.
SV3002 – Fluent setting with regulator.
SV3003 - Switch in position ON means „1" and in position OFF means „0". (pict.1)
You can see combinations of „1" and „0" for reach (switch S1, S2), time (switch S3, S4, S5) and twilight (switch S6, S7,
S8) setting in charts below.
Nastavení dosahu (citlivost)
Reach is to be understood as the diameter of more or less circular detection zone on the floor (ceiling mounting)
that is covered by sensor´s signal, which detects the movement.
SV3002 - Fluent setting, radius 2-8m (±10%)
SV3003 - Default values, radius 2m | 5m | 10m (±10%)
Time setting (switch-off delay)
Selected time interval begins with each detected movement. We recommend setting the function on minimum
during test.
SV3002 - Fluent setting, 8s (±5s) to 12 min (±30s)
SV3003 - default values, 12s | 3min | 15min | 30min
1
0
Nastavení soumraku (světelná citlivost)
We recommend setting the function on maximum during test.
SV3002 - Fluent setting, 2-2000lux (±5%)
SV3003 - Default values, 10lx | 100lx | 500lx | 2000lx (±10%)
Stated information may differ according to position and installation height.
Position marked - or applies to minimum and position marked
If the product is mechanically damaged or connected unprofessionally, guarantee cannot be allowed
RADAR SENZOR
Recessed
or
applies to maximum.
+
All right reserved.
Technical data can be changed without previous notice.
UM_SV300X_101217