O p e r a t i n g
1
V
FUSE
ON/OFF
mA
VOLTAGE
–
8
Operating controls
OUTPUT
Turns outputs on/off
5 V 1 A
5 V output, adjustable within ±10% of 5 V with
a screwdriver. Max. 1 A, short-circuit proof.
20 V output on the left
V / mA / Fuse
Selection of voltage or current display V/mA
Selection of current limiting or electronic
fuse function
Display
3 digit display (7segment LED)
V
LED voltage display selected
mA LED current display selected
F
LED of electronic fuse activated
I
LED indication of current limit
max
reached
VOLTAGE
Adjustment of voltage 0 .. 20 V
0 – 20 V
Safety terminals for left 20 V output
22
Subject to change without notice
c o n t r o l s
2
3
TRIPLE POWER SUPPLY HM8040-
F
CURRENT
0 – 20 V
+
–
0.5 A
9
10
4
5
6
3
ON
F
OUTPUT
Instruments
PUSH LONG
VOLTAGE
+
–
5 V
1 A
11
12
CURRENT
Adjustment of current limit I
20 V output on the right
V / mA / Fuse
Selection of voltage or current display V/mA
Selection of current limiting or electronic
fuse function
Display
3 digit display (7segment LED)
V
LED voltage display selected
mA LED current display selected
F
LED of electronic fuse activated
I
LED indication of current limit
max
reached
VOLTAGE
Adjustment of voltage 0 .. 20 V
0 – 20 V
Safety terminals of right 20 V output
CURRENT
Adjustment of current limit I
7
V
FUSE
ON/OFF
mA
CURRENT
0 – 20 V
+
0.5 A
13
14
= 0 .. 0.5 A
max
= 0 .. 0.5 A
max