Figure 5 HCT-HV1 Hand-piece Assembly
Figure 6 HCTA-TH1

4. Setup and unit operation

1. Basic unit setup
1.
Connect the hand-piece assembly, HCT-HV1, to the power supply.
2.
Plug the power cord into the power connector (Figure 2). Plug the power cord
into a grounded wall socket of the rated input line voltage.
3.
Turn On the unit by pressing the Power button  momentarily.
4.
To Abort a Profile (to the Cool-Down zone*) press and hold the  (red) on the
footswitch or  (red) on the hand-piece down while in Run Mode.
5.
Once the cool zone is finished, turn off the unit by pressing the Power button
 momentarily. Note ~ you must be out of set-up mode in order to do this. I.e.
no flashing numbers on the display.
2. System Mode Selection
The HCT-1000 has two system modes of operation.
The first mode is HCT. In this mode, the HCT-1000 is used as a standalone
handheld convection rework tool.
The second mode is MRS. In this mode, the HCT-1000 is used as part of a
Modular Rework System. The unit is connected via cable to a PCT-1000 and
may be used with the ATH-1100A Adjustable Tool Holder. In this mode the
HCT-1000 provides timing control for both units and the ATH-1100A allows
repeatable place and remove operations.
Plug the Communications Cable into the Communication Connector (Figure 2
above) on the HCT-1000 and the PCT-1000. When connected in MRS mode
the time setting on the PCT-1000 will display "- -".
Selection of the System mode is made in Setup mode, refer to section 3.1.
Additional operational options are available, refer to section 3.5.
3. Operational Mode Selection
Vacuum Pick-up Tube
Adjustment
é (blue) Vacuum Activation
ê (red) Profile Start/Abort
Heater Assembly
Vacuum Pick-up Tube
Figure 7
4